Step B-28. Replace the lower exit guide plate.
Replace with the NEW lower exit guide plate.
Install all the new parts except for the film and the 2
clamps, which are affixed and cannot be removed.
NEW film and clamps to be installed additionally.
OLD guide plate
B-6
NEW guide plate
(D4472327 )
Step B-29. Replace with the NEW shift tray exit driven rollers.
New
Old
T
echnical
Not
removable
Wider cuts
B-10
Remove the E-rings (x4) attached to both sides of the roller,
install the new rollers on the new shaft, and secure the rollers with the E-ring.
B
ulletin
Date:
15-Jun-11
Following 2 parts to be reused:
Sensor bracket
Sensor
Clamp x2
B-7
Attach the NEW film
(D4472326A) here.
Deviation to be within 1mm
New Clamp x2
(11050717)
B-8
New Rollers (D4342459 )
B-9
New Shaft (D4472879)