Model:
Aries-P1.5/C1.5, AG-P1/C1, AGL-P1/C1
Subject: Procedure for Adjusting the CIS LED upon
Replacement of the CIS Unit
From:
PP Tech Service Dept., 1st PP Tech Service Sect.
Classification:
This RTB has been issued to announce the CIS LED adjustment procedure which is
required when replacing the CIS unit.
Please add this procedure to your field service manual in the section:
4. Replacement and Adjustments > Paper Registration > CIS Unit
Procedure
TCRU screws
1. Remove the cover [A]. (TCRU screw x 2)
2. Remove the CIS unit [A]. (screw x2, connector x1)
echnical
T
Troubleshooting
Mechanical
Paper path
Product Safety
Connector
Screws
ulletin
B
Date:
06-Jun-12
Prepared by: J. Kobayashi
Part information
Electrical
Transmit/receive
Other (Additional
Information)
[A]
[A]