Reissued:18-Apr-14
Model:
Aries-P1.5/C1.5
e) Slide in a piece of paper in と the doctor gap to remove developer stuck in the gap.
f)
Use a vacuum cleaner to remove the remaining particles.
IMPORTANT: Work carefully to avoid damage to the development rollers.
g) Follow the above steps in reverse order to put back the development unit.
4. Do "No.208 Execute Toner Refreshing" in the Adjustment Settings for Skilled Operators
Menu so that clumps of toner/developer are removed and do not clog the doctor gap.
5. Run the customer job.
Are the results accepted by the customer?
Yes: Finished
No: Repeat steps 2 and 3 because the development unit still contains clumps of
toner/developer.
6. Replace the developer of the affected color by referring to the procedures in RTB
RM077072a, if the doctor gap is still clogged even after repeating steps 2~4 twice.
echnical
T
B
ulletin
Date:
16-May-11
PAGE: 9/10
No.:
RM077031d