5 — ONT management using an ONT interface
Parameter
Mode
String format
SLID value
This section shows you how to:
view or retrieve the current SLID setting
clear (reset) the SLID
enter or modify a SLID
Prerequisites
The prerequisites are:
To enter a SLID, the user access level of the ONT is read-write.
To view current SLID settings, the user access level of the ONT is read only, or
read-write.
The ONT must have a SLID value of null or default before you can enter a new
SLID. To reset a SLID to its default value, you must clear it.
The steps to access the interface are completed.
5-56
Value
Volatile
Permanent
Registration
Hexadecimal
Alphanumeric
DEFAULT
Non-default value
See Procedure
5-1
for HTTP interface using the first Ethernet port.
See Procedure
5-3
for CLI interface using the craft port.
See Procedure
5-6
for HTTP interface for Package C ONTs.
See Procedure
5-7
for Package C ONT CLI interface using the craft port.
See Procedure
5-8
for Package C ONT CLI interface using an Ethernet port.
December 2010
ONT Product Information Guide Edition 01
Table 5-10 SLID settings
Description
In volatile mode:
The SLID at the ONT returns to its default value
after the ONT is powered off and on.
The SLID is delivered to the P-OLT in the
proprietary mode, which uses the proprietary
PLOAM message.
In permanent mode:
The SLID at the ONT retains its configured value
after the ONT is powered off and on.
The SLID is delivered to the P-OLT in the
proprietary mode, which uses the proprietary
PLOAM message.
In registration mode:
The SLID at the ONT retains its configured value
after the ONT is powered off and on.
The SLID is delivered to the P-OLT in registration
ID mode, which uses the password PLOAM message
defined in G.984.3.
Hexadecimal string of 0 to 9 and usually a to f or A to
F, with zeroes appended to a length of 20 characters
String of up to 10 characters (default)
The ONT is set to a default value.
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
3FE 54017 AAAA TCZZA

Advertisement

loading

This manual is also suitable for:

7302