To activate an ONT using the serial number, the following is required:
The ONT must be provisioned at the P-OLT with its serial number, a dummy
SLID, provisioning data, and services.
The ONT with the corresponding serial number must be installed at the customer
site.
The ONT must be connected to the GPON.
To activate an ONT using the SLID, the following is required:
The ONT must be provisioned at the P-OLT with a dummy serial number, its
SLID, provisioning data, and services.
The ONT with any serial number must be installed at the customer site.
The SLID in the ONT must be cleared locally, if the ONT has a non-default SLID.
The SLID must be entered locally into the ONT.
The ONT must be connected to the GPON.
Activation of an ONT can also be initiated by the P-OLT automatically at regular
intervals or when one or more formerly registered and active ONTs become inactive.
In both cases, the frequency of the P-OLT polling is programmed by the user.
The SLID at the ONT can be stored in volatile or non-volatile mode. In volatile
mode, the SLID is delivered to the P-OLT in proprietary mode; in non-volatile mode,
the SLID can be delivered to the P-OLT in registration ID or proprietary mode. The
SLID can be entered in hexadecimal or alphanumeric string format. See Table
for more information about SLID settings
Alcatel-Lucent 7330/7302 ISAM FTTN R04.02.41
3FE 54017 AAAA TCZZA
Note —
The ONT and its services can be preprovisioned at the
P-OLT before or after the ONT is installed.
Note —
If you are reusing an ONT that was previously configured
with a non-volatile SLID, the SLID must be reset to its default value.
If you are reusing an ONT that was previously configured with a
volatile SLID, the SLID will automatically return to its default value
when the ONT is powered off and on.