No.
Name
U070 Selection of thread clamping position
Selection of enable / disable of thread
U071
breakage detection
Number of stitches to be sewn while
U072
the thread breakage detection is disa-
bled at the beginning of sewing
Number of stitches to be sewn while
U073
the thread breakage detection is disa-
bled during sewing
U076 Selection of the feed method
Setting of the feed timing (reference at
U077
the end of sewing)
Setting of the feed timing (continuous
U078
feed)
Setting of the feed timing (constant
U079
speed feed)
Opening / closing of the feeding frame
U081
control pedal
Opening / closing of the feeding frame
U082
control during temporary stop
With / without the latch for pedal
U084
switch 1
With / without the latch for pedal
U085
switch 2
With / without the latch for pedal
U086
switch 3
Selection item
0: Standard (Front position)
1: Back position
0: Thread breakage detection is disa-
bled
1: Thread breakage detection is ena-
bled
0: Intermittent feed
1: Continuous feed
2: Constant speed feed
0: Without
1: With
0: Without
1: With
0: Without
1: With
Setting
Unit &
range
Meaning
HS3020RSZ
0 to 1
-
0 to 1
-
0 to 15
1 stitch
0 to 15
1 stitch
0 to 2
-
-10 to 30
1
-30 to 30(°)
1 (°)
-30 to 30(°)
1 (°)
0 to 99
1
0 to 99
1
0 to 1
-
0 to 1
-
0 to 1
-
– 82 –
Initial value
GS3020RSZ
HS3020RSW
GS3020RSW
1
1
8
3
1
0
0
0
0
0
1
1
1