No.
Name
U030 Setting of the thread tension output
U032 Buzzer selection
Number of stitches to be sewn before
U033
the thread clamp releases the thread
Setting the thread clamp driving timing
(reference: 80 °)
U034
Set with 4 ° (TG resolution)
+ : Advanced  - : Retarded
Thread handling at the beginning of
U035
sewing
Selection of lifting of the feeding frame
U037
at the end of sewing
Prohibition of lift of the feeding frame
U038
at the end of sewing
With/without origin retrieval at the end
U039
of sewing (for normal operation)
Selection item
0: Standard (linear)
1: Low-tension detailed setting
2: Hight-tension detailed setting
0: Without buzzer sound
1: Panel operating sound
2: Panel operating sound + error
0: Thread clamping
1: Thread trimming
2: No handling
0: Feeding frame goes up after re-
turning to the sewing start position
1: Feeding frame goes up and returns
to the sewing start position
2: Feeding frame goes up when the
feeding frame switch is pressed
after returning to the sewing start
position
3: Feeding frame goes up when the
feeding frame switch is pressed
after moving to the sewing start
position / sewing machine starts
sewing with the start switch
0: Normal
1: Prohibition of lift of the feeding
frame
0: Without origin retrieval
1: With origin retrieval
Setting
Unit &
range
Meaning
HS3020RSZ
0 to 2
-
0 to 2
-
1 to 7
1 stitch
-40 to 0(°)
1 (°)
0 to 2
-
0 to 3
-
0 to 1
-
0 to 1
-
– 80 –
Initial value
GS3020RSZ
HS3020RSW
GS3020RSW
0
2
2
0
1
0
0
0