② Changing over the supply voltage of the electrical box of the AW-3 device
Change the con-
nection of the black
wire according to
the supply voltage
specification.
Color of wire
Color of wire
(White)
Terminal number
1
1
1
NOTE : Correspondence table of the supply voltage and the voltage changeover
MC-702 electrical box, connection
Supply voltage
200 V
220 V
230 V
240 V
( Black )
Input voltage
4
200V
5
220V
6
240V
terminal
V +
200 V
220 V
230 V
240 V
1. Turn OFF the power switch. Wait for five min-
utes or more.
2. Detach the cover from the electrical box of
this device.
3. Change over the connection of the connector
to the terminal block according to the supply
voltage specification.
Electrical box of the AW-3 device,
connection terminal
V -
Black wire
0 V
4 (200 V)
0 V
5 (220 V)
0 V
6 (240 V)
0 V
6 (240 V)
– 16 –
White wire
1 (0 V)
1 (0 V)
1 (0 V)
1 (0 V)