Setting log parameters
You can configure two types of logs: critical logs and system logs.
• Critical log (Critical.log):
The Critical log saves Reboot and Firmware update events. The size of the Critical.log file is
greater than 300Kb and you can save more than 600 events.
• System log (System.log):
According to the System.log parameter for Log Level, and whether or not saving the log is
enabled, you can save all kinds of system log information, such as network, SIP, RF, etc. The
size of the System.log file is approximately 1Mb.
The Log Level determines the corresponding system log parameters as follows:
- Level 1: INFO log saved.
- Level 2: INFO and ERROR logs are saved (Default).
- Level 3: INFO, ERROR and WARNING logs are saved. Set this level for heavy testing and
RF-related problems.
- Level 4: INFO, ERROR and WARNING and DEBUG logs are saved. Set this level for
system and SIP-related problems.
- Level 5: INFO, ERROR, WARNING, DEBUG and TRACE logs are saved.
Downloading statistical information
You can download statistical information using the Statistic Information link. Clicking on the link
downloads the StatisticInformation.log file that contains the parameters listed in the table found
under
Statistics information
April 2020
on page 63.
Installing and Administering D100 SIP Wireless Phones
Overview
67