Jog - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Extended setpoint channel

2.5 Jog

2.5
Jog
This function can be selected via digital inputs or via a fieldbus (e.g. PROFIBUS). This
means that the setpoint is specified via p1058[0...n] and p1059[0...n].
When a jog signal is present, the motor is accelerated to the jog setpoint with the
acceleration ramp of the ramp-function generator (referred to the maximum speed p1082;
see figure "Flow diagram: Jog 1 and jog 2"). After the jog signal has been deselected, the
motor is decelerated via the set ramp of the ramp-function generator.
Note
The "Jog" function is not PROFIdrive-compliant!
Figure 2-2
Figure 2-3
64
Flow diagram: Jog and OFF1
Flow diagram: Jog 1 and jog 2
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Drive functions

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents