8.5 Thermal motor protection
Temperature measurement
● p0600[0...n] = 20 or 21 activates the motor temperature sensing via an external sensor.
● p0601[0...n] = 11 sets the evaluation for several temperature channels.
● p0608[0...3] allocates the temperature channels for the motor temperatures to signal
● p0609[0...3] allocates the temperature channels for the motor temperatures to signal
● p4100[0...n] = 0 deactivates temperature evaluation.
● r4101[0...3] indicates the actual resistance value of the respective temperature sensor.
● p4102[0/2/4/6] sets the alarm thresholds of the temperature sensors to between -48° C
● p4102[1/3/5/7] sets the fault thresholds of the temperature sensors to between -48° C
● p4102[0...7] = 251° C deactivates the alarm and/or fault message that has been set.
● p4610[0...n] to p4613[0...n], assigns up to four temperature sensors to the motor and
● r4620[0...3] ≠ -200° C means:
● r4620[0...3] = -200° C means:
KTY84
● p4100[0...3] = 2 assigns the temperature sensor type KTY84 to a corresponding channel
● r4105[0...3] displays the actual temperature value of the measuring channel involved of
546
source 2.
source 3.
The maximum measurable resistance is 2170 Ω.
and 250° C.
and 250° C.
defines the responses.
– a KTY84 is connected
– the temperature display is valid.
– a PTC or a bimetal NC contact is connected
– there is a temperature sensor fault
– the sensor channel is deactivated
– the temperature evaluation is deactivated
1 to 4, and activates the evaluation.
the temperature evaluation. If no sensor has been selected or if the actual temperature
value is invalid, the value -300° C is in the parameter.