Description

Description
The motor changeover is used in the following cases, for example:
● Changing over between different motors and encoders
● Changing over different windings in a motor (e.g. star-delta changeover)
● Adapting the motor data
If several motors are operated alternately on a Motor Module, a matching number of drive
data sets must be created.
Note
For the "VECTOR" control mode, the following applies:
To connect to a rotating motor, the "flying restart" function must be activated (p1200).
Note
When changing over the drive data set between several motors that physically exist with
integrated holding brakes, it is not permissible that the internal brake control is used.