10.1 Communication according to PROFIdrive
Bit
Meaning
8
Travel to fixed stop
(not with telegrams 9, 110)
9
Reserved
10
Reserved
11
Motor changeover
12
Master sign-of-life bit 0
13
Master sign-of-life bit 1
14
Master sign-of-life bit 2
15
Master sign-of-life bit 3
STW1_BM (control word 1, metal industry)
See function diagram [2425].
Table 10- 10 Description of STW1_BM (control word 1, metal industry)
Bit
Meaning
0
ON/OFF1
1
OFF2
Note:
Control signal OFF2 is generated by ANDing BI: p0844 and BI: p0845.
2
OFF3
Note:
Control signal OFF3 is generated by ANDing BI: p0848 and BI: p0849.
3
Enable operation
640
Remarks
1
Select "Travel to fixed stop"
The signal must be set before the fixed stop is
reached.
1/0
Deselect "Travel to fixed stop"
The signal must be set before the fixed stop is
reached
-
-
-
-
0/1
Motor changeover complete
0
No effect
-
User data integrity (4-bit counter)
-
-
-
Remarks
0/1
ON
Pulse enable possible
0
OFF1
Braking with the ramp-function generator, then
pulse suppression and switching on inhibited.
1
No OFF2
Enable possible
0
Immediate pulse suppression and switching on
inhibited
1
No OFF3
Enable possible
0
Quick stop (OFF3)
Braking with OFF3 ramp p1135, then pulse
suppression and switching on inhibited.
1
Enable operation
Pulse enable possible
0
Disable operation
Cancel pulses
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Parameter
BI: p1545
-
-
BI: p0828[0]
CI: p2045
Parameter
BI: p0840
BI: p0844
BI: p0848
BI: p2816.0