Infeed
1.1 Active Infeed
Overview of important parameters (see SINAMICS S120/S150 List Manual)
• p3410
• r3411
• r3412
• p3560
1.1.6

Active Infeed open-loop control

The Active Line Module can be controlled via the BICO interconnection using terminals or
the fieldbus. The operating status is indicated on the operating display r0002. The missing
enable signals for operation (r0002 = 00) are mapped in parameter r0046. The EP terminals
(enable pulses) must be connected in accordance with the manual of the corresponding
power units. The drive unit must have been commissioned for the first time.
Acknowledging faults
Faults that are still present but the causes of which have been rectified can be
acknowledged using a 0/1 edge at the "1st acknowledge faults" signal (p2103).
34
Infeed identification method
Infeed identified inductance
Infeed DC-link capacitance identified
Infeed Vdc controller proportional gain
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3