6.2

Reference parameters/normalizations

Reference values, corresponding to 100%, are required for the display of units as
percentages. These reference values are entered in parameters p2000 to p2007. They are
computed during the calculation through p0340 = 1 or in STARTER during drive
configuration. After calculation in the drive, these parameters are automatically protected via
p0573 = 1 from boundary violation through a new calculation (p0340). This eliminates the
need to adjust the references values in a PROFIdrive controller whenever a new calculation
of the reference parameters via p0340 takes place.
Figure 6-1
Note
If a referenced form is selected and the reference parameters (e.g. p2000) are changed
retrospectively, the referenced values of some of the control parameters are also adjusted to
ensure that the control behavior is unaffected.
Using STARTER offline
After the offline drive configuration, the reference parameters are preset. You can call the
configuration of these parameters via the menu path "Drive > Configuration". On the
"Disabled list" tab, the parameters can be changed and protected.
Note
If the reference values (p2000 to p2007) are changed offline in STARTER, it can lead to limit
violations of the parameter values, which cause alarms or faults when loading to the drive
unit.
Drive functions
Function Manual, (FH1), 01/2013, 6SL3097-4AB00-0BP3
Illustration of conversion with reference values
6.2 Reference parameters/normalizations
Basic functions
271