LOGO! functions
4.4 Special functions list - SF
4.4.12

Yearly timer

Short description
The output is controlled by means of a configurable on/off date. You can configure the timer
to activate on a yearly, monthly, or user-defined time basis. With any mode, you can also
configure the timer to pulse the output during the defined time period. The time period is
configurable within the date range of January 1, 2000 to December 31, 2099.
Note
Because LOGO! 24/24o does not have a real-time clock, the yearly timer is not available for
both versions.
Symbol in LOGO!
Timing diagrams
Example 1: Yearly mode on, Monthly mode off, Pulse Off, On Time = 2000-06-01, Off Time =
2099-08-31: Every year on June 1 the timer output switches on and remains on until August
31.
190
Wiring
Description
Cam parameter
At the Cam parameter, you configure the timer mode,
the on-/off-times for the timer, and whether the output
is a pulse output.
Output Q
Q is set when the configured cam is switched on.
Manual, 04/2011, A5E03556174-01