LOGO! functions
4.4 Special functions list - SF
Valid ranges of the timebase, if T = Actual value of an already-programmed function
Timebase
ms
s
m
The display in programming mode (example):
If the referenced block (B6, in the example) returns a value that lies out of the valid range,
the value is rounded up or down to the next valid value.
Parameter preset = Actual value of an already-programmed function
How to include the actual value of an already-programmed function:
1. Press
2. Press
3. Press
4. Press
162
max. value
99990
5999
5999
to move the cursor to the equal sign of parameter T.
to change the equal sign into an arrow. If it exists, the last referenced block and
its timebase is shown.
to move the cursor to the "B" of the shown block, and then press
required block number.
to move the cursor to the block's timebase and press
timebase.
Meaning
Number of ms
Number of s
Number of min