O: Keypad-Related Settings; O1: Keypad Display - YASKAWA GA800 Programming Manual

Ac drive for industrial applications
Table of Contents

Advertisement

1.13 o: Keypad-Related Settings

1.13

o: Keypad-Related Settings

o1: Keypad Display

No.
Name
(Hex.)
o1-01
User Monitor Selection
(0500)
RUN
o1-02
Monitor Selection at
Power-up
(0501)
RUN
o1-03
Frequency Display Unit
Selection
(0502)
o1-04
V/f Pattern Display Unit
(0503)
o1-05
LCD Contrast
Adjustment
(0504)
RUN
o1-10
User Units Maximum
Value
(0520)
o1-11
User Units Decimal
Position
(0521)
o1-24 to o1-35:
Custom Monitor 1 to 12
(11AD - 11B8)
RUN
o1-36
LCD Backlight
Brightness
(11B9)
RUN
o1-37
LCD Backlight ON/OFF
Selection
(11BA)
RUN
o1-38
LCD Backlight Off-Delay
(11BB)
RUN
o1-39
Show Initial Setup Screen
(11BC)
RUN
100
V/f
CL-V/f
OLV
CLV
AOLV
Sets the U monitor for the Drive Mode. This parameter is only available when you use an
LED keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the monitor item that the keypad screen shows after energizing the drive. Refer to "U:
Monitors" for information about the monitor items that the keypad screen can show. This
parameter is only available when you use an LED keypad.
1 : Frequency Reference (U1-01)
2 : Direction
3 : Output Frequency (U1-02)
4 : Output Current (U1-03)
5 : User Monitor (o1-01)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the display units for the frequency reference and output frequency.
0 : 0.01Hz units
1 : 0.01% units
2 : min
-1
(r/min) unit
3 : User Units
V/f
CL-V/f
OLV
CLV
AOLV
Sets the setting unit for parameters that set the V/f pattern frequency.
0 : Hz
1 : min
-1
(r/min) unit
V/f
CL-V/f
OLV
CLV
AOLV
Sets the contrast of the LCD display on the keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the value that the drive shows as the maximum output frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of decimal places for frequency reference and monitor values.
0 : No Decimal Places (XXXXX)
1 : One Decimal Places (XXXX.X)
2 : Two Decimal Places (XXX.XX)
3 : Three Decimal Places (XX.XXX)
V/f
CL-V/f
OLV
CLV
AOLV
Sets a maximum of 12 monitors as user monitors. This parameter is only available when
using an LCD keypad.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the intensity of the LCD keypad backlight.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the automatic shut off function for the LCD backlight.
0 : OFF
1 : ON
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time until the LCD backlight automatically turns off.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to show the LCD keypad initial setup screen each time the drive is
energized. This parameter is only available when using an LCD keypad.
0 : No
1 : Yes
Description
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
Ref.
(Range)
106
511
(104 - 855)
1
511
(1 - 5)
Determined by A1-02
511
(0 - 3)
Determined by A1-02
512
(0, 1)
5
513
(0 - 10)
Determined by o1-03
513
(1 - 60000)
Determined by o1-03
513
(0 - 3)
o1-24: 101
513
o1-25: 102
o1-26: 103
o1-27 to o1-35: 0
(0, 101 - 999)
5
514
(1 - 5)
1
514
(0, 1)
60 s
514
(10 - 300 s)
1
514
(0, 1)

Advertisement

Table of Contents
loading

Table of Contents