L7: Torque Limit; L8: Drive Protection - YASKAWA GA800 Programming Manual

Ac drive for industrial applications
Table of Contents

Advertisement

1.11 L: Protection Functions
No.
Name
(Hex.)
L6-10
Mech Fatigue Detect
Delay Time
(046A)
L6-11
Mech Fatigue Hold Off
Time
(046B)

L7: Torque Limit

No.
Name
(Hex.)
L7-01
Forward Torque Limit
(04A7)
RUN
L7-02
Reverse Torque Limit
(04A8)
RUN
L7-03
Forward Regenerative
Trq Limit
(04A9)
RUN
L7-04
Reverse Regenerative Trq
Limit
(04AA)
RUN
L7-06
Torque Limit Integral
Time
(04AC)
L7-07
Torque Limit during
Accel/Decel
(04C9)
L7-16
Torque Limit Process at
Start
(044D)
L7-35
Low Freq Regen Torque
Limit Lvl
(1B57)
Expert
L7-36
Regen Torque Limit
Derate Freq
(1B58)
Expert

L8: Drive Protection

No.
Name
(Hex.)
L8-01
3% ERF DB Resistor
Protection
(04AD)
L8-02
Overheat Alarm Level
(04AE)
L8-03
Overheat Pre-Alarm
Selection
(04AF)
88
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time for mechanical deterioration detection.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time that the drive will start mechanical deterioration detection triggered by the
cumulative operation time of the drive.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit value for forward motoring as a percentage, where motor rated torque
is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit value for reversed motoring as a percentage, where motor rated torque
is the 100% value.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit value for forward regenerative conditions as a percentage of the motor
rated torque.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit value for reversed regenerative conditions as a percentage of the
motor rated torque.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the integral time constant for the torque limit function.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit function during acceleration and deceleration.
0 : Proportional only
1 : Proportional & Integral control
V/f
CL-V/f
OLV
CLV
AOLV
Assigns a time filter to allow the torque limit to build at start.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the torque limit used during low-speed regeneration. Usually it is not necessary to
change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency width at which L7-35 [Low Freq Regen Torque Limit Lvl] operates.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to enable braking resistor protection with a Yaskawa ERF series braking
resistor (3% ED) installed on the heatsink.
0 : Disabled
1 : Enabled
V/f
CL-V/f
OLV
CLV
AOLV
Sets the oH detection level in temperature.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the operation of drives when an oH alarm is detected.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
4 : Operate at Reduced Speed (L8-19)
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
Description
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Default
Ref.
(Range)
0.1 s
471
(0.0 - 10.0 s)
0 h
471
(0 - 65535 h)
Default
Ref.
(Range)
200%
472
(0 - 300%)
200%
473
(0 - 300%)
200%
473
(0 - 300%)
200%
473
(0 - 300%)
200 ms
473
(5 - 10000 ms)
0
474
(0, 1)
1
474
(0, 1)
50.0%
474
(0.0 - 200.0%)
6.0 Hz
475
(0.0 - 30.0 Hz)
Default
Ref.
(Range)
0
475
(0, 1)
Determined by o2-04,
475
C6-01
(50 - 150 °C)
3
475
(0 - 4)

Advertisement