No.
Name
(Hex.)
H6-03
Terminal RP Function
Gain
(042E)
RUN
H6-04
Terminal RP Function
Bias
(042F)
RUN
H6-05
Terminal RP Filter Time
(0430)
RUN
H6-06
Terminal MP Monitor
Selection
(0431)
RUN
H6-07
Terminal MP Frequency
Scaling
(0432)
RUN
H6-08
Terminal RP Minimum
Frequency
(043F)
H6-09
Voltage Phase Sync MP
Selection
(156E)

H7: Virtual MFIO selection

No.
Name
(Hex.)
H7-00
Virtual MFIO selection
(116F)
Expert
H7-01
Virtual Multi-Function
Input 1
(1185)
Expert
H7-02
Virtual Multi-Function
Input 2
(1186)
Expert
H7-03
Virtual Multi-Function
Input 3
(1187)
Expert
H7-04
Virtual Multi-Function
Input 4
(1188)
Expert
H7-10
Virtual Multi-Function
Output 1
(11A4)
Expert
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the gain used when the function in H6-01 [Terminal RP Pulse Train Function] is input
to terminal RP.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the bias used when the function in H6-01 [Terminal RP Pulse Train Function] is input
to terminal RP. Sets a value at the time when the pulse train is 0 Hz.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time constant for the pulse train input primary delay filters.
V/f
CL-V/f
OLV
CLV
AOLV
Sets a function for pulse train monitor output terminal MP. Sets the "x-xx" part of the Ux-xx
monitor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency of the pulse train output signal used when the monitor set with H6-06
[Terminal MP Monitor Selection] is 100%.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the minimum frequency of the pulse train signal that terminal RP can detect.
V/f
CL-V/f
OLV
CLV
AOLV
Set whether to output the pulse synchronized with drive output voltage phase from the
pulse train monitor output terminal MP. This parameter is only enabled when H6-06 = 102
[Terminal MP Monitor Selection = Output Frequency] and H6-07 = 0 [Terminal MP
Frequency Scaling = 0 Hz].
0 : Disabled
1 : Enabled
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to
operate the virtual I/O function.
0 : No
1 : Yes
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enters the virtual input set in H7-10 [Virtual Multi-Function Output
1].
Note:
Settings 1B [Programming Lockout] and 11B [!Programming Lockout] are not
available.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enters the virtual input set in H7-12 [Virtual Multi-Function Output
2].
Note:
Settings 1B [Programming Lockout] and 11B [!Programming Lockout] are not
available.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enters the virtual input set in H7-14 [Virtual Multi-Function Output
3].
Note:
Settings 1B [Programming Lockout] and 11B [!Programming Lockout] are not
available.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that enters the virtual input set in H7-16 [Virtual Multi-Function Output
4].
Note:
Settings 1B [Programming Lockout] and 11B [!Programming Lockout] are not
available.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function for virtual digital output 1.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
1.10 H: Terminal Functions
Default
Ref.
(Range)
100.0%
428
(0.0 - 1000.0%)
0.0%
428
(-100.0 - 100.0%)
0.10 s
429
(0.00 - 2.00 s)
102
429
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851
- 855)
1440 Hz
430
(0 - 32000 Hz)
0.5 Hz
430
(0.1 - 1000.0 Hz)
0
430
(0, 1)
Default
Ref.
(Range)
0
431
(0, 1)
F
431
(1 - 19F)
F
431
(1 - 19F)
F
431
(1 - 19F)
F
432
(1 - 19F)
F
432
(0 - 1A7)
1
79

Advertisement

Table of Contents
loading