E2: Motor Parameters - YASKAWA GA800 Programming Manual

Ac drive for industrial applications
Table of Contents

Advertisement

No.
Name
(Hex.)
E1-12
Mid Point B Voltage
(030B)
Expert
E1-13
Base Voltage
(030C)
Expert

E2: Motor Parameters

No.
Name
(Hex.)
E2-01
Motor Rated Current
(FLA)
(030E)
E2-02
Motor Rated Slip
(030F)
E2-03
Motor No-Load Current
(0310)
E2-04
Motor Pole Count
(0311)
E2-05
Motor Line-to-Line
Resistance
(0312)
E2-06
Motor Leakage
Inductance
(0313)
E2-07
Motor Saturation
Coefficient 1
(0314)
E2-08
Motor Saturation
Coefficient 2
(0315)
E2-09
Motor Mechanical Loss
(0316)
Expert
E2-10
Motor Iron Loss
(0317)
E2-11
Motor Rated Power
(0318)
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets a middle point voltage for the V/f pattern.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the base voltage for the V/f pattern.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated current in amps.
V/f
CL-V/f
OLV
CLV
AOLV
Sets motor rated slip.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the no-load current for the motor in amps when operating at the rated frequency and
the no-load voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
Note:
• When A1-02 = 0, 1, 3 [Control Method Selection = V/f, CL-V/f, CLV], the maximum
value is 120.
• When A1-02 = 2, 4 [OLV, AOLV], the maximum value is 48.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the line-to-line resistance for the motor stator windings.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the voltage drop from motor leakage inductance when the motor is operating at the
rated frequency and rated current. This value is a percentage of Motor Rated Voltage.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron-core saturation coefficient at 50% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron-core saturation coefficient at 75% of the magnetic flux.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the mechanical loss of the motor. It is set as a percentage of E2-11 [Motor Rated
Power]. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor iron loss.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated output in the units from o1-58 [Motor Power Unit Selection].
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
1.8 E: Motor Parameters
Default
Ref.
(Range)
0.0 V
303
(200 V Class: 0.0 to 255.0
V, 400 V Class: 0.0 to
510.0 V)
0.0 V
303
(200 V Class: 0.0 - 255.0
V,400 V Class: 0.0 -
510.0 V)
Default
Ref.
(Range)
Determined by o2-04,
303
C6-01
(10% to 200% of the
drive rated current)
Determined by o2-04,
303
C6-01
(0.000 - 20.000 Hz)
Determined by o2-04,
304
C6-01
(0 to E2-01)
4
304
(2 - 120)
Determined by o2-04,
304
C6-01
(0.000 - 65.000 Ω)
Determined by o2-04,
305
C6-01
(0.0 - 60.0%)
0.50
305
(0.00 - 0.50)
0.75
305
(E2-07 - 0.75)
0.0%
305
(0.0 - 10.0%)
Determined by o2-04,
305
C6-01
(0 - 65535 W)
Determined by o2-04,
305
C6-01
(0.00 - 650.00 HP)
1
45

Advertisement

Table of Contents
loading

Table of Contents