T4: EZ Tuning

No.
Name
(Hex.)
T4-01
EZ Tuning Mode
Selection
(3130)
T4-02
Motor Type Selection
(3131)
T4-04
Motor Rated Revolutions
(3133)
T4-05
Motor Rated Frequency
(3134)
T4-06
Motor Rated Voltage
(3135)
T4-07
Motor Rated Current
(3136)
T4-08
Motor Rated Capacity
(3137)
T4-09
Number of Poles
(3138)
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of Auto-Tuning for EZOLV control.
0 : Motor Parameter Setting
1 : Line-to-Line Resistance
V/f
CL-V/f
OLV
CLV
AOLV
Sets the type of motor.
0 : Induction (IM)
1 : Permanent Magnet (PM)
2 : Synchronous Reluctance (SynRM)
V/f
CL-V/f
OLV
CLV
AOLV
Sets rated rotation speed (min
-1
) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated frequency (Hz) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated voltage (V) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the rated current (A) of the motor.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor rated power in the units set in o1-58 [Motor Power Unit Selection].
V/f
CL-V/f
OLV
CLV
AOLV
Sets the number of motor poles.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
1.16 T: Motor Tuning
Default
Ref.
(Range)
0
539
(0, 1)
0
540
(0, 1, 2)
-
540
((40 Hz to 120 Hz) × 60 ×
2/E9-08)
Determined by E9-01 and
540
o2-04
(40.0 - 120.0 Hz)
200 V Class: 230.0 V, 400
540
V: 460.0 V
(200 V Class: 0.0 - 255.0
V,400 V Class: 0.0 -
510.0 V)
Determined by o2-04,
540
C6-01
(10% to 200% of the
drive rated current)
Determined by E9-10
540
(0.10 - 650.00 HP)
Determined by E9-01
540
(2 - 48)
111