L: Protection Functions; L1: Motor Protection - YASKAWA GA800 Programming Manual

Ac drive for industrial applications
Table of Contents

Advertisement

1.11

L: Protection Functions

L1: Motor Protection

No.
Name
(Hex.)
L1-01
Motor Overload (oL1)
Protection
(0480)
L1-02
Motor Overload
Protection Time
(0481)
L1-03
Motor Thermistor oH
Alarm Select
(0482)
L1-04
Motor Thermistor oH
Fault Select
(0483)
L1-05
Motor Thermistor Filter
Time
(0484)
L1-08
oL1 Current Level
(1103)
L1-09
oL1 Current Level for
Motor 2
(1104)
L1-13
Motor Overload Memory
Selection
(046D)
YASKAWA TOEPYAIGA8002B GA800 Drive Programming
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the motor overload protection with electronic thermal protectors.
0 : Disabled
1 : Variable Torque
2 : Constant Torque 10:1 Speed Range
3 : Constant Torque 100:1 SpeedRange
4 : PM Variable Torque
5 : PM Constant Torque
6 : Variable Torque (50Hz)
Note:
When only one motor is connected to a drive, set L1-01 = 1 to 6 [Enabled]. External
thermal relays are not necessary in these conditions.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the operation time for the electronic thermal protector of the drive to prevent damage
to the motor. Usually it is not necessary to change this setting.
V/f
CL-V/f
OLV
CLV
AOLV
Sets drive operation when the PTC input signal entered into the drive is at the oH3 [Motor
Overheat Alarm] detection level.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
3 : Alarm Only
V/f
CL-V/f
OLV
CLV
AOLV
Sets the drive operation when the PTC input signal to the drive is at the oH4 [Motor
Overheat Fault (PTC Input)] detection level.
0 : Ramp to Stop
1 : Coast to Stop
2 : Fast Stop (Use C1-09)
V/f
CL-V/f
OLV
CLV
AOLV
Sets the primary delay time constant for the PTC input signal entered to the drive. This
parameter prevents accidental motor overheat faults.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the reference current for the motor 1 thermal overload detection. When the current
level > 0.0 A, you cannot set this value < 10% of drive rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the reference current for the motor 2 thermal overload detection. When the current
level > 0.0 A, you cannot set this value < 10% of drive rated current.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the function that keeps the current electronic thermal protector value when the drive
stops receiving power.
0 : Disabled
1 : Enabled
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM

1.11 L: Protection Functions

Default
Ref.
(Range)
Determined by A1-02
436
(0 - 6)
1.0 min
439
(0.1 - 5.0 min)
3
440
(0 - 3)
1
440
(0 - 2)
0.20 s
440
(0.00 - 10.00 s)
0.0 A
440
(0.0 A or 10% to 150% of
the drive rated current)
0.0 A
441
(0.0 A or 10 to150% of
the drive rated current)
1
441
(0, 1)
1
81