Trane TR200 Programming Manual page 45

Hide thumbs Also See for TR200:
Table of Contents

Advertisement

Parameter Description
[37]
Display Text 1
[38]
Display Text 2
[39]
Display Text 3
[89]
Date and Time Readout
[953]
Profibus Warning Word
[1005]
Readout Transmit Error
Counter
[1006]
Readout Receive Error
Counter
[1007]
Readout Bus Off Counter
[1013]
Warning Parameter
[1115]
LON Warning Word
[1117]
XIF Revision
[1118]
LonWorks Revision
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
[1601]
Reference [Unit]
[1602] * Reference %
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor voltage
[1613]
Frequency
4-8
Enables an individual text string to be written, for display in the keypad
or to be read via serial communication.
Enables an individual text string to be written, for display in the keypad
or to be read via serial communication.
Enables an individual text string to be written, for display in the keypad
or to be read via serial communication.
Displays the current date and time.
Displays Profibus communication warnings.
View the number of CAN control transmission errors since the last pow-
er-up.
View the number of CAN control receipt errors since the last power-up.
View the number of Bus Off events since the last power-up.
View a DeviceNet-specific warning word. One separate bit is assigned to
every warning.
Shows the LON-specific warnings.
Shows the version of the external interface file of the Neuron C chip on
the LON option.
Shows the software version of the application program of the Neuron C
chip on the LON option.
View the number of running hours of the motor.
View the line power consumption in kWh.
View the control word sent from the adjustable frequency drive via the
serial communication port in hex code.
Total reference (sum of digital/analog/preset/bus/freeze ref./catch up and
slow-down) in selected unit.
Total reference (sum of digital/analog/preset/bus/freeze ref./catch up and
slow-down) in percent.
Present status word
View the two-byte word sent with the status word to the bus master re-
porting the main actual value.
View the user-defined readouts as defined in par.0-30
Unit, par.0-31
Custom Readout Min Value
Max
Value.
Actual power consumed by the motor in kW.
Actual power consumed by the motor in HP.
Voltage supplied to the motor.
Motor frequency, i.e., the output frequency from the adjustable frequen-
cy drive in Hz.
Custom Readout
and par.0-32
Custom Readout
TR200 Programming Guide

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents