61) Measure input shaft thrust play.
Apply dial gauge onto input shaft end (1) and measure thrust
play of input shaft.
Special tool
(A): 09900-20607
(B): 09900-20701
Input shaft thrust play: 0.3 – 0.9 mm (0.012 – 0.035 in.)
62) After applying A/T fluid to new O-ring, fit it to breather union
(2). Then install breather union to transaxle case.
63) Install breather hose (1).
64) Wipe off and clean mating surface between transaxle case
(1) and torque converter housing.
65) Apply sealant to torque converter housing (1) by using a
nozzle (2) as shown in figure by such amount that its section
is 1.2 mm (0.047 in.) in diameter.
"A": Sealant 99000-31230
66) Install torque converter housing to transaxle case, tighten
bolts to specified torque.
CAUTION:
Apply sealant to threads of four bolts shown in figure
before tightening.
"A": Sealant 99000-31230
Tightening torque
Torque converter housing bolts
(a): 33 N·m (3.3 kg-m, 24.0 lb-ft)
AUTOMATIC TRANSAXLE 7B-195