Suzuki Ignis Service Manual page 1732

Rg413
Table of Contents

Advertisement

Test
Work Order Description
T07
Check: Interruption of Voltage Supply Circuit
• Measure voltage between the following terminals:
Circuit Fuse – Input contact
&
Ground
Yes: E04
T08
Check: Short to Ground/Interruption of Voltage Supply Circuit
• Ignition OFF
• Disconnect wiring harness connector from:
Ignition Switch
• Measure voltage between the following terminals:
Ignition Switch – Wiring harness connector (wiring harness side) terminal
G24-5
&
Ground
Yes: E05
T09
Check: Short to Ground/Interruption of Voltage Supply Circuit
• Remove electrical component from socket:
Circuit Main Fuse
• Check the following component for proper operation:
Circuit Main Fuse
Yes: T10
T10
Check: Interruption of Voltage Supply Circuit
• Measure voltage between the following terminals:
Circuit Main Fuse – Input contact
&
Ground
Yes: E06
T11
Check: Short to Ground of Voltage Supply Circuit
• Connect fused jumper wire to:
Circuit Main Fuse – Output contact
&
Battery voltage
• Check the following component for proper operation:
Fuse of the fused jumper wire
Yes: T12
T12
Check: Short to Ground of Voltage Supply Circuit
• Remove fused jumper wire
• Connect fused jumper wire to:
Ignition Switch – Wiring harness connector (wiring harness side) terminal
G24-4
&
Battery voltage
• Check the following component for proper operation:
Fuse of the fused jumper wire
Yes: T13
ENGINE GENERAL INFORMATION AND DIAGNOSIS (Z13DT ENGINE) 6-3-73
Nominal Value
greater than 11 V
No: T08
greater than 11 V
No: T09
Test okay?
No: T11
greater than 11 V
No: E07
Test okay?
No: E13
Test okay?
No: E12

Advertisement

Table of Contents
loading