Test
Work Order Description
T06
Check: Short to Ground/Interruption of Voltage Supply Circuit
• Ignition OFF
• Disconnect wiring harness connector from:
A/C Compressor
• Connect fused jumper wire to:
ECM – Wiring harness connector (wiring harness side) terminal G88-79
&
Ground
• Ignition ON
• Measure voltage between the following terminals
A/C Compressor – Wiring harness connector (wiring harness side) termi-
nal D32-1
&
Ground
Yes: T07
T07
Check: Circuit Interruption of Ground Circuit
• Ignition OFF
• Remove fused jumper wire
• Measure resistance between the following terminals
A/C compressor – Wiring harness connector (wiring harness side) termi-
nal D32-2
&
Ground
Yes: T08
T08
Check: Component
• Connect wiring harness connector to:
A/C Compressor
• Connect fused jumper wire to:
Compressor Relay – Socket terminal E55-3
&
Battery voltage
• Clicking noise from following component:
A/C Compressor
Yes: E01
T09
Check: Short to Ground/Interruption of Voltage Supply Circuit
• Remove electrical component from socket:
Circuit Fuse
• Check the following component for proper operation:
Circuit Fuse
Yes: T10
T10
Check: Interruption of Voltage Supply Circuit
• Measure voltage between the following terminals:
Circuit Fuse – Input contact
&
Ground
Yes: E09
ENGINE GENERAL INFORMATION AND DIAGNOSIS (Z13DT ENGINE) 6-3-259
Nominal Value
greater than 11 V
No: E04
less than 5 Ohm
No: E03
Test okay?
No: T02
Test okay?
No: T11
greater than 11 V
No: E10