G71Mpp Or Slp98 Furnace Setting Adjustments; Wi-Fi Connection - Lennox iComfort S30 Installation And Setup Manual

Ultra smart thermostat
Hide thumbs Also See for iComfort S30:
Table of Contents

Advertisement

Up to 8-conductor thermostat wire from the non-communicating
furnace terminal strip to the equipment interface module (R, C, O, Y1,
Y2, G, W1, W2 and W3).
Wiring as required for accessories
2. DO NOT cut any option link on furnace control.
3. After the entire system is wired, power up the system; the thermostat will
check the system for installed communication devices.
4. During commissioning you will arrive at the equipment found screen. From
there touch non-communicating equipment to add non-communicating
equipment.
5. From the add/remove equipment screen, touch either 1-Stage A/C unit
or 2-Stage A/C unit.
6. Touch the done to return to the equipment found screen. Touch continue
to proceed to the next screen.
7. Continue with the commissioning sequence. When the set up airflow
per zone screen appears, you can adjust blower, heating and cooling
circulation air flows. When done, touch continue to proceed.
8. The dealer control center will appear next. Touch tests to access the test
section
9. Here you will have another opportunity to adjust blower circulation, heating
and cooling circulation air flows. Use the plus or minus buttons to adjust
up or down the CFM settings. Once adjustments are completed, press
continue.
10. Under the select test to run screen, you may un-check any tests not
required, or run all tests. Touch start tests to proceed. Once each test
section is completed, touch continue to proceed to the next group of tests.
11. Once all test are completed, touch done. This will return you to the select
tests to run screen. If finish, press the back arrow (<) at the top left-hand
of the screen to return to the dealer control center.
12. Touch exit to return to the home screen.

G71MPP or SLP98 Furnace Setting Adjustments

If your thermostat is being used with either a G71MPP or SLP98 furnace
and is set to variable-capacity mode of operation (the iComfort default with
these units), the system's settings for stage timers are ignored (even if shown
enabled in the thermostat). The stage timer will be used on the cooling side
for other cooling units except when modulating outdoor units are used. The
furnace software sets and controls the firing rates. The only other controlling
factor is the stage temperature differentials. In Load-Tracking Variable Capacity
(default for these furnaces), both stage timers and temperature differentials
are ignored.

Wi-Fi Connection

This is for connecting the thermostat to a secure home wireless network.
NOTE: A router with Bonjour capabilities is required for this function. Check
the router functions if Smart Hub do not connect. Apple Bonjour
implementation of zero-configuration networking (Zeroconf), a group
of technologies that includes service discovery, address assignment,
and host name resolution.
NOTE: Never use a home guest account. Never use an open router connection
(non-secure). Always use a secure connection physically located in
the home where the thermostat is located.
Home Wi-Fi Access Point is Visible
1. Go to menu > settings > wi-fi ,
2. Slide the option to ON to enable Wi-Fi.
3. Wi-Fi network will show not connected. Press on not connected to
display a list of available access points.
4. Select a network will be displayed listing all detected networks within
range. Select your home network by pressing on the network name.
NOTE: The thermostat can connect to a home wireless router that uses up to
32 characters in the access point name (visible or hidden).
5. When connecting to a secure home Wi-Fi network, a password will be
requested. Enter your home Wi-Fi network password and press join to
continue.
NOTE: If you wish to see the characters you are typing, check show password.
The thermostat will support up to a 63 character password. The
password cannot contain the % or # symbols.
Home Wi-Fi Access Point is Hidden
1. Slide the option to ON to enable Wi-Fi.
2. Wi-Fi network will show not connected. Press on not connected.
3. Select other.
4. The "enter new network information" screen will appear. Enter the name of
the hidden network.
NOTE: The thermostat can connect to a home wireless outer that uses up to
32 characters in the access point name (visible or hidden).
5. Select Security. Options are: none, WEP, WPA and WPA2. If your home
Wi-Fi connection is unsecured, then Wi-FI security must be enabled using
WEP, WPA or WPA2 via the router before proceeding. Consult your router
documentation on how to enable Wi-Fi security.