Led Indicators; Terminals; Mag-Mount Led And Installation; Installation - Lennox iComfort S30 Installation And Setup Manual

Ultra smart thermostat
Hide thumbs Also See for iComfort S30:
Table of Contents

Advertisement

The push button has a LED associated with it that indicates the status of the
Smart Hub commissioning state (see "Table 1. LED Indicators").
lED I
nDICators
Table 1. LED Indicators
System Status LED
LED Color
Status
Description
System is nor-
A solid green LED indicates no system errors are detected.
Green
mal
System operating as designed.
Red
HVAC Fault
System has critical alert which needs attention.
Blinking amber LED indicates either Wi-Fi is not connected,
Amber
Wi-Fi Error
no Wi-Fi is within range, or and Wi-Fi hardware error. Could
also indicate intermittent Wi-Fi connection.
Blinking magenta LED indicates either Mag-Mount or HD
Magenta
Thermostat Error
display not connected.
Cyan
HVAC Error
Indoor unit is not connected or unable to communicate.
Commissioning Status LED
System is
No mobile device is directly connected using Wi-Fi to the
Blue
normal
Smart Hub.
Blinking green LED indicates the commissioning button has been activated and
Green
the Smart Hub is waiting for a connection with a mobile device.
Green
A solid green LED indicates a mobile device is connected to the Smart Hub.
• If multiple errors are present, the system status LED will display each active error for one
second on and one second off and then display the next error if present.
• The system will continue to cycle through all active errors.
• System status errors are displayed in the following priority: HVAC , thermostat and then Wi-Fi.
t
ErmInals
Table 2. Terminal Designations
Terminal Designation
Description
R
24VAC input
I+
RSBUS I+
I-
RSBUS I-
C
24VAC return
ACC1*
Accessory 1 and 2 (FOR
FUTURE USE)
ACC2*
+
12VDC output
-
12VDC return
A
Communications bus A
* ACC1 and ACC2 are for future use. DO NOT USE.

Mag-Mount LED and Installation

Magnets located in this product have far-reaching and strong magnetic fields.
They could damage TVs and laptops, computer hard drives, credit and ATM
cards, data storage media, mechanical watches, hearing aids and speakers.
Keep HD Display and Mag-Mount away from devices and objects that could
be damaged by strong magnetic fields.
I
nstallatIon
Use the following procedure for installation of the Mag-Mount where existing
thermostat wiring does not exist:
1. Unpack the HD Display and Mag-Mount (wall base).
2. Determine the best location to install Mag-Mount. Ideal location should be
Terminal Color
Red
Yellow
3. Cut or drill a small hole for thermostat wiring.
Green
Black
Orange
White
Blue
4. Pull about three inches of thermostat wire through the opening and remove
Black
Yellow
5
Table 2. Terminal Designations
Terminal Designation
Description
B
Communications bus B
CAUTION
Mag-Mount without
access cover installed.
Access Cover
located away from outside wall, direct sunlight or discharge air vents.
3/8" (10 mm)
Diameter Hole
the outer thermostat wire jacket.
Terminal Color
Green
Wall Plate
(Use is optional)

Hide quick links:

Advertisement

Table of Contents
loading