G71MPP or SLP98 Furnace Setting Adjustment

®
If your iComfort
S30 is being used with either a G71MPP or SLP98 furnace and is set to variable-capacity mode of operation (the iComfort
units), the system's settings for stage timers are ignored (even if shown enabled in the S30 Control System). The stage timer will be used on the cooling side for
other cooling units except the XC20, SL18XC1/XP1 and XC/XP25 where they are not used. The furnace software sets and controls the firing rates. The only
other controlling factor is the stage temperature differentials. In Load-Tracking Variable Capacity (default for these furnaces), both stage timers and temperature
differentials are ignored.
FCC Compliance Statement — Part 15.19
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference
that may cause undesired operation.
FCC Interference Statement — Part 15.105 (b)
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
S
Reorient or relocate the receiving antenna.
S
Increase the separation between the equipment and receiver.
S
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
S
Consult the dealer or an experienced radio/TV technician for help.

RF Exposure Information

This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. In order to avoid the possibility of exceeding the
FCC radio frequency exposure limits, human proximity to the antenna shall not
be less than 20cm during normal operation.

Replacement Parts

®
The following iComfort
S30 component parts can be ordered:
Catalog #
Component
12X97
HD Display
12X98
Smart Hub
12X99
Mag-Mount
13X01
Wall plate
X5393
Temporary Wall plate

Replacement iComfort Component Controls

These kits have been set up for replacement of the iComfort
note that control kits are unit-specific.
Table 1. Replacement Controls
®
iComfort
Unit
G71MPP (rev. 03 or later)
SLP98 (rev. 01 or later)
SL280 (rev. 02 or later)
EL296 (rev. 01 or later)
CBX40UHV (rev. 02 or later) and CBX32MV
(rev. 06 or later)
XC17
XP17 and XP17N
XP19 (rev. 06 or later)
XC21 (rev. 04 or later) and SL18XC
SL18XP, XP21 and XP21N
XP20 and XP25
XC20 and XC25
42
®
default with these
Remarks
Thermostat interface
Control base
Wall mount for HD Display
Wall plate for Mag-Mount (use is
optional)
For electrical J box installation
®
controls. Please
Replacement Kit
Control Part #
Catalog #
65W69
605341-01
10G43
102813-03
83W88
103130-03
83W88
103130-03
65W70
605341-02
11H36
103369-04
11H36
103369-04
11H36
103369-04
11H36
103369-04
11H36
103369-04
13U31
103686-05
13U31
103686-05