Parameter
Description
Equipment
PureAir Filter
Default: ON. Options are either ON or OFF.
This parameter turns on and off the filter life and UV lamp life reporting. When set to off, the control will continue to calculate the remaining filter life through continu-
ous sampling, but will not use filter tests to determine filter life. The control will:
• Perform a filter calibration upon indication of a filter change regardless of the value of this parameter.
Dirty Filter
Detection and UV
• Perform a UVA lamp calibration upon indication of a lamp change regardless of the value of this parameter.
Life Detection
• Calculate UVA lamp life remaining regardless of the value of this parameter.
Alarms 504 and 503 will not be sent while this parameter is set to "Off"
The Diagnostics screen on the thermostat will continue to show values for both filter life and UV lamp life regardless of the value of this parameter.
Default is 100%, Range is 50% to 100% Changes can be made in increments of 10%. This parameter:
Max Air Filtered
• Modifies the amount of air that is allowed to pass through the filter after a valid % life determination before a filter test is initiated.
between Tests
• Expressed as a percentage of the cubic feet of air that would pass through the filter if the fan operated at continuous fan CFM for 30 days.
UV lamp operation
Default: ON. Options are either ON or OFF.
detection
Filter Life
Provides percentage of remaining filter life. This is for display purposes only and cannot be changed.
Last replacement
Date last filter reset was accomplished. This is for display purposes only and cannot be changed
date for filter
Purifier life
Provides percentage of remaining purifier life. This is for display purposes only and cannot be changed
Last replacement
Date last purifier insert reset was accomplished. This is for display purposes only and cannot be changed
date for purifier
reset PureAir S will reset all PureAir S parameters back to factory defaults.
reset purifier will reset it to 100%. This is usually accomplished after the purifier insert has been replaced.
reset filter will reset it to 100%. This is usually accomplished after the air filter has been replaced.
Parameter
Description
Restart Smart Hub
Restarts the Smart Hub.
Re-configure
Re-configure HVAC system.
System
Reset HVAC
Resets all HVAC equipment.
Equipment
Factory Reset
Resets thermostat to factory default settings.
Thermostat
Factory Reset
Resets Smart Hub parameters back to factory default.
Smart Hub
Table 12. PureAir S Parameters