Initial notification of critical alerts will pop up on the home screen and will be listed under notification menu. Minor and moderate alerts are found only under the notification menu.
* Current Lennox modulating outdoor units are XC20, XP20, XC25 and XP25.
Applicable
Alert
Priority
System
Code
Condition
Component(s)
65545
Minor
S30 System

Installation Checklist

Smart Hub Checks:
1
Is the Smart Hub properly mounted to either a wall stud or wall? (Do not mount on equipment or ductwork)
Is communication status LED (green) visible? When LED is active it indicates that 24VAC is present at the Smart Hub. It also indicates communication is active
2
between Smart Hub, Mag-Mount and HD Display.
3
Are all terminal wiring properly connected and tight?
4
When required, is either or both the discharge (DATS) and outdoor (OAS) air sensors properly connected and isolated when used?
Mag-Mount Checks:
1
Are all terminal wiring properly connected and tight?
Is the solid blue LED visible when the HD Display is removed? This indicates all wiring is correct. Blinking blue LED indicates the A and B communication wires are
2
reversed.
3
Is the solid blue LED not visible when the HD Display is removed? This usually indicates 12VDC to + and - is not present at the Mag-Mount terminals.
HD Display Checks:
1
Is the HD Display properly placed and connected to Mag-Mount? When properly connected, the Mag-Mount blue LED will be off.
Is the screen blank after initial power-up? The HD Display may take up to three minutes before anything appears on the screen due to a HD Display low battery
2
condition. HD Display battery charging only occurs when connected to the Mag-Mount.
System Checks
1
Is the Wi-Fi connected?
2
Can the homeowner access the consumer portal (www.myicomfort.com) from either a PC or tablet?
3
Has the homeowner downloaded the Lennox Thermostat application from either Google Play or IOS App Store to their mobile devices?
4
Is the Lennox Dealer account number or your main shop phone number been added to the dealer information screen?
5
If applicable, has the air handler's electric heat strips been commissioned? If not, commissioning of heat strips must be performed.
Has a complete system test been run? If not, from the HD Display home screen go to settings > advance settings > view dealer control center > and select
6
tests.
Table 18. Alert Codes and Troubleshooting
Actual
Displayed Alert
Component or System Operational State and Troubleshooting Tip
Text
This indicates the system is not running cooling mode in optimized efficiency. There may be a
component or components that will require attention.
NOTE:
Currently this is a minor alert and will not generate an email notification to the dealer
Cooling
or homeowner. Parameter settings for this feature are hidden for the software version
Prognostics
3.2 release. The information will be used for data collection only and sent to the Lennox
Alert (capacity
server.
alert)
This algorithm will determine whether the unit will run out of capacity during the hottest time
of summer. It will look back everyday a minimum of three days to see if there is a pattern and
compare it to the hottest day on record for that zip code before triggering an alert. It must see a
pattern before it will trigger the alert.
75
How to clear alert code
The system will continue to count
the number occurrences within
a 24 hours period where system
demand is not achieved. Will
clear once cooling demand is
achieved.
YES
NO
YES
NO
YES
NO
YES
NO