Parameter
Description
This provides information on unit code, language supported, equipment type name, control software revision, control model number, control serial number, control hard-
ware revision, protocol revision number, device product level, 24VAC average power consumption, 24VAC peak power consumption, compatible devices list, application
About
code memory size, micro-controller part number, max number of zones, supported damper types, number of damper positions, zone temp sensor 1, zone temp sensor
2, zone temp sensor 3 and zone temp sensor 4.
Equipment Name
A unique name can be assigned to this component. Name can be up to 29 characters. Name can consist of letters, numbers, special characters and spaces.
Zones 1 through
4 Temp Reading
Allows adjustment to temperature reading displayed on zone thermostat.
Calibration
Reset Zoning
Any installer modifications under the zoning control tab will be reset back to the factory defaults if the reset zoning control option is used.
Control
Parameter
Description
About
This screen provides information concerning model number, serial number, hardware revision, software revision, language support and equipment type name.
Auto Brightness
Options are on and off. Default is off.
Brightness Value
The brightness range is 0 - 100. Default 80. Touch either the + or - button to increase or decrease the setting.
Display Air
Options are on and off. Default is off. Air Quality is displayed under the weather display. Touch the Weather icon on the home page to see the current air quality.
Quality
Display Indoor
Options are on and off. Default is off.
Humidity
Display Outdoor
Options are on and off. Default is off.
Weather
Outdoor
Temperature
Options are off, Internet (AccuWeather) or sensor. Default is Internet (AccuWeather).
Source
Proximity Control
Options are ON and OFF. Default is OFF. Is used to wake-up the display from screen saver mode when motion near the HD Display is detected.
Reset thermostat
Resets the thermostat settings to factory default.
Screen Locked
Options are unlocked, partially locked and locked. Default is unlocked.
Screen Saver
Options are off, weather, power save and logo. Default is off.
Options are ON and OFF. Default is OFF. This allows a wider low and high temperature. Normal range is 60 to 90°F (15.6 to 32.2°C) . When this parameter is set to ON,
Wide Setpoint
the range is 40 to 100°F (4.4 to 37.8°C). This feature can also be set through the user interface setting screen. From the home screen go to menu > settings > heat &
cool (or it may be just heat or cool) > wider set-point range.
Parameter
Description
About
This provides information on equipment type name, control hardware revision, control software revision, control serial number and control model number.
Table 9. Zoning Control Parameters
Table 10. Thermostat (HD Display) Parameters
Table 11. Mag-Mount Parameters
36

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents