Technical data
11.2 Input point
11.2
Input point
Gauge pressure input
Measured variable
Span (fully adjustable) or
measuring range, max.
operating pressure (in
accordance with
97/23/EC Pressure
Equipment Directive) and
max. test pressure
(pursuant to DIN 16086)
(for oxygen
measurement, max.
100 bar and 60 °C
ambient
temperature/process
temperature
)
Lower measuring limit
Measuring cell with
•
silicone oil filling
Measuring cell with
•
inert liquid
Upper measuring limit
Start of scale value
176
HART
Gauge pressure
Span
Maximum
operating
pressure
MAWP (PS)
0.01 ...
4 bar g
1 bar g (0.15
(58 psi g)
... 14.5 psi g)
0.04 ...
7 bar g
4 bar g (0.58
(102 psi g)
... 58 psi g)
0.16 ...
21 bar g
16 bar g (2.3
(305 psi g)
... 232 psi g)
0.63 ... 63 bar
67 bar g
g (9.1 ...
(972 psi g)
914 psi g)
1.6 ...
167 bar g
160 bar g (23
(2422 psi g)
... 2321 psi g)
4 ... 400 bar g
400 bar g
(58 ...
(5802 psi g)
5802 psi g)
7.0 ...
800 bar g
700 bar g
(11603 psi g)
(102 ...
10153 psi g)
30 mbar a (0.44 psi a)
30 mbar a (0.44 psi a)
100% of max. span (max. 100 bar g
(1450 psi g) for oxygen measurement)
ambient temperature/process temperature
60°C
Between the measuring limits (fully adjustable)
PROFIBUS PA and FOUNDATION Fieldbus
Maximum test
Measuring
pressure
range
6 bar g
1 bar g
(87 psi g)
(14.5 psi g)
10 bar g
4 bar g
(145 psi g)
(58 psi g)
32 bar g
16 bar g
(464 psi g)
(232 psi g)
100 bar g
63 bar g
(1450 psi g)
(914 psi g)
250 bar g
160 bar g
(3626 psi g)
(2321 psi g)
600 bar g
400 bar g
(8702 psi g)
(5802 psi g)
800 bar g
700 bar g
(11603 psi g)
(10153 psi g)
100% of max. measuring range (max.
100 bar g (1450 psi g) for oxygen
measurement) ambient temperature/process
temperature 60°C
Operating Instructions, 06/2013, A5E00047092-09
Maximum
Maximum test
operating
pressure
pressure
4 bar g
6 bar g
(58 psi g)
(87 psi g)
7 bar g
10 bar g
(102 psi g)
(145 psi g)
21 bar g
32 bar g
(305 psi g)
(464 psi g)
67 bar g
100 bar g
(972 psi g)
(1450 psi g)
167 bar g
250 bar g
(2422 psi g)
(3626 psi g)
400 bar g
600 bar g
(5802 psi g)
(8702 psi g)
800 bar g
800 bar g
(11603 psi g)
(11603 psi g)
SITRANS P DS III with HART