Siemens SITRANS P DS III Operating Instructions Manual page 51

Pressure transmitter with hart
Hide thumbs Also See for SITRANS P DS III:
Table of Contents

Advertisement

Installation type for gauge pressure and level measurements (open containers)
Installation type A
Installation type B
H
≤ 7 m (23 ft); with halocarbon oil as the filling liquid, only H
1
Key
p
MA
p
ME
ρ
FL
ρ
oil
g
H
U
H
O
H
1
For absolute pressure measurements (vacuum), install the measuring device at least at the
height of the remote seal or below it (see installation types C).
SITRANS P DS III with HART
Operating Instructions, 06/2013, A5E00047092-09
Pressure transmitter above the
measuring point
Pressure transmitter below the
measuring point
Start of scale value
Full-scale value
Density of the process medium in the container
Density of the filling oil in the capillary line of the remote seal
Acceleration due to gravity
Lower filling level
Upper filling level
Distance between the container flange and the pressure transmitter
4.5 "Remote seal" installation
Start of scale value:
p
= ρ
* g * H
+ ρ
MA
FL
U
oil
Full-scale value:
p
= ρ
* g * H
+ ρ
ME
FL
O
oil
Start of scale value:
p
= ρ
* g * H
- ρ
MA
FL
U
oil
Full-scale value:
p
= ρ
* g * H
- ρ
ME
FL
O
oil
≤ 4 m(13.1 ft)
1
Installing/mounting
* g * H
1
* g * H
1
* g * H
1
* g * H
1
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents