Modbus (Channel 1); Slave Address (Sw); Slave Address (Hw) (Read Only); Baud Rate - Siemens FST020 Function Manual

Sitrans f series ultrasonic flowmeters ip65 nema 4x
Table of Contents

Advertisement

Communication

5.2 Modbus (Channel 1)

Related
Path
5.2
Modbus (Channel 1)
5.2.1

Slave address (SW)

Description
The slave address (SW) for the Modbus device can be configured. This address is used if
the DIP switch is set to 0.
Setting
Default
Related
Path
5.2.2

Slave address (HW) (read only)

Description
The slave address (HW is determined by the DIP switch setting on the transmitter cassette
and can be read out in this parameter. This address is used if the DIP switch is set to a value
> 0.
Options
Related
Path
5.2.3

Baud rate

Description
Baud rate of Modbus interface.
Setting
Default
174
Communications → Service channel (USB) → MSD connect
1 to 247
Communication → Modbus (Channel 1) → Slave address (SW)
Read only
Communication → Modbus (Channel 1) → Slave address (HW)
9600 Bit/s; 19200 Bit/s; 115200 Bit/s; 38400 Bit/s; 57600 Bit/s; 76800 Bit/s; 1200 Bit/s;
2400 Bit/s; 4800 Bit/s
FST020 Function manual
Function Manual, 09/2017, A5E42949526-AA