How To Show/Hide Displayed Data - Furuno FCV-2100 Operator's Manual

Fish size indicator
Hide thumbs Also See for FCV-2100:
Table of Contents

Advertisement

1. OPERATION
Menu item
[Bottom Fish Start Depth]
[Bottom Fish Depth
Range]
[Fish Level]
[Temperature]*
[Temperature Alarm Trig-
ger Temp.]*
[Water Temperature
Range]*
[Fish Size Graph]
[Fish Graph Scale
Threshold]
[Combined Alarm]
*: Requires connection to a temperature sensor.
5. Select [Apply] to save the current changes and change or adjust other settings.
Select [OK] to save the current changes and close the menu window.
Select [Cancel] to abort all changes and close the menu window.
1.22

How To Show/Hide Displayed Data

Various data received from connected sensors can be shown on screen, or hidden, at
any time.
To show/hide data, select the [Data Display] icon (
then, referring to the figure below, select the data to show on-screen.
1-36
Set the starting depth for the bottom fish alarm. The distance set here
is measured from the location of the transducer face.
Set the range (distance from [Bottom Fish Start Depth]) for the fish
alarm.
Set the echo strength at which the fish alarms are triggered. This set-
ting is for both the [Fish Alarm] and the [Bottom Fish Alarm].
• [Weak]: Echoes stronger than light blue trigger the alarm.
• [Medium]: Echoes stronger than yellow trigger the alarm.
• [Strong]: Echoes stronger than red trigger the alarm.
Set the temperature alarm type.
• [In range]: The alarm is triggered when the temperature is within the
set range.
• [Out of range]: the alarm is triggered when the temperature is outside
the set range.
Set the start point for the temperate alarm range.
Set the range for the temperature alarm.
Select the fish size(s) which trigger the Fish Size Graph Alarm. Multiple
selections are available.
Set the distribution rate at which to trigger the alarm. For example, a
settings of [30%] will trigger the alarm when the distribution rate for the
selected sizes is over 30%.
Set a combination of two or more alarms. Referring to the list below, se-
lect the alarms to include in the combination. Active selections are
marked with a "tick" in the box to the left.
• Bottom: Bottom alarm
• Fish (Normal): Standard fish alarm
• Fish (B/L): Bottom fish alarm
• Temperature: Temperature alarm
• Fish Size Graph: Fish size graph alarm
Own ship location
(latitude/longitude)
Speed Over
the Ground
Water temperature
Description
) from the InstantAccess bar™,
Time and date
Speed Through
the Water

Advertisement

Table of Contents
loading

Table of Contents