Furuno FCV-2100 Installation Manual

Furuno FCV-2100 Installation Manual

Fish size indicator
Hide thumbs Also See for FCV-2100:

Advertisement

Quick Links

Installation Manual
FISH SIZE INDIDCATOR
FCV-2100
Model
(Product Name: FISH FINDER)
SAFETY INSTRUCTIONS ................................................................................................ i
SYSTEM CONFIGURATION ........................................................................................... ii
EQUIPMENT LISTS........................................................................................................ iii
1. MOUNTING..............................................................................................................1-1
1.1 Processor Unit ...................................................................................................................1-1
1.2 Transceiver Unit.................................................................................................................1-2
1.3 Transducer.........................................................................................................................1-3
1.4 Trackball Control Unit ........................................................................................................1-4
1.5 Monitor (Local Supply) .......................................................................................................1-7
2. WIRING....................................................................................................................2-1
2.1 Processor Unit ...................................................................................................................2-1
2.2 Transceiver Unit.................................................................................................................2-6
2.3 Data Sentences ...............................................................................................................2-14
3. INITIAL SETTINGS..................................................................................................3-1
3.1 How to Set the Language and Measurement Unit .............................................................3-1
3.2 How to Set the Service Menu ............................................................................................3-2
3.3 Communication Port Setting ..............................................................................................3-5
3.4 External Echo Sounder Setting..........................................................................................3-7
3.5 Calibration Setting............................................................................................................3-10
3.6 Stabilization Setting .........................................................................................................3-14
3.7 Reset to Default Setting ...................................................................................................3-17
APPENDIX 1 JIS CABLE GUIDE .............................................................................AP-1
PACKING LISTS ......................................................................................................... A-1
OUTLINE DRAWINGS ................................................................................................ D-1
INTERCONNECTION DIAGRAM ................................................................................ S-1
www.furuno.com
All brand and product names are trademarks, registered trademarks or service marks of their respective holders.

Advertisement

Table of Contents
loading

Summary of Contents for Furuno FCV-2100

  • Page 1: Table Of Contents

    Installation Manual FISH SIZE INDIDCATOR FCV-2100 Model (Product Name: FISH FINDER) SAFETY INSTRUCTIONS ....................i SYSTEM CONFIGURATION ................... ii EQUIPMENT LISTS......................iii 1. MOUNTING......................1-1 1.1 Processor Unit ........................1-1 1.2 Transceiver Unit.........................1-2 1.3 Transducer.........................1-3 1.4 Trackball Control Unit ......................1-4 1.5 Monitor (Local Supply) .......................1-7 2.
  • Page 2 7KH SDSHU XVHG LQ WKLV PDQXDO LV HOHPHQWDO FKORULQH IUHH )85812 $XWKRUL]HG 'LVWULEXWRU'HDOHU  $VKLKDUDFKR 1LVKLQRPL\D  -$3$1 $  $35  3ULQWHG LQ -DSDQ $OO ULJKWV UHVHUYHG &  -$1    3XE 1R ,0(& '$0, )&9           ...
  • Page 3: Safety Instructions

    - Keep the cable away from oil and fuels. is solely responsible for the proper - Keep the cable away from locations installation of the equipment. FURUNO where it may be damaged during the will assume no responsibility for any installation.
  • Page 4: System Configuration

    SYSTEM CONFIGURATION Monitor Processor Unit FCV-2101 Trackball Control Unit TCU-001 Navigational Equipment Net Sonde Satellite Compass™ 24 VDC USB Device Server Rectifier UDS-001 100/110/220/ PR-62 USB Device 230 VAC, 1ø, 50/60 Hz Trackball Control Unit TCU-001 Ethernet Hub HUB-101 24 VDC Network Fish Finder (DFF3/DFF1-UHD) 24 VDC...
  • Page 5: Equipment Lists

    EQUIPMENT LISTS Standard Supply Name Type Code No. Remarks Processor unit FCV-2101 Transceiver unit FCV-2102 Transducer FCV-2103 Trackball control unit TCU-001 Installation materials CP02-09500 000-030-008 For processor unit CP02-09300 000-029-457 For transceiver unit CP14-06801 001-303-390 For trackball control unit Accessory FP19-01801 001-205-650 For processor unit...
  • Page 6 EQUIPMENT LISTS This page is intentionally left blank.
  • Page 7: Mounting

    MOUNTING NOTICE Do not apply paint, anti-corrosive sealant or contact spray to coating or plastic parts of the equipment. Those items contain organic solvents that can damage coating and plastic parts, especially plastic connectors. Processor Unit The processor unit can be installed on a tabletop or bulkhead. When selecting a mounting location, keep in mind the following points: •...
  • Page 8: Transceiver Unit

    1. MOUNTING 2. Drill four pilot holes in the bulkhead or panel on a tabletop for self-tapping screws. Refer to the outline drawing at back of this manual for mounting dimensions. 3. Fasten four self-tapping screws ( 6x20) into the pilot holes, leave 5 mm protrud- ing.
  • Page 9: Transducer

    1. MOUNTING • Face the cable connectors downward for bulkhead mount. Connectors Connectors How to mount the transceiver unit 1. Drill four pilot holes in the bulkhead or tabletop for self-tapping screws. 2. Screw two self-tapping screws ( 5x20) into the lower pilot holes, leave 5 mm pro- truding.
  • Page 10: Trackball Control Unit

    1. MOUNTING • Orient the transducer fore mark to ship’s bow within ±5 degree. It is known that air bubbles are fewest at the place where the bow first falls and the next wave raises, at usual cruising speed. In small, slow-speed boats, the position between 1/2 and 2/3 of the φ...
  • Page 11 1. MOUNTING • Locate the unit away from places subject to water splash and rain. • Leave sufficient clearance at the sides and rear of the unit to facilitate maintenance. • Determine the location considering the length of the signal cable between this unit and the processor unit.
  • Page 12 1. MOUNTING Surface mounting 1. Drill four holes ( 4) on the table re- ferring to the outline drawing at the back of this manual. 2. Secure the trackball control unit with four screws (M3, local supply) from the underside of the table. The length of screws should be de- termined depending on the thick- ness of panel.
  • Page 13: Monitor (Local Supply)

    FM1 assemblies. FM1 assy. Monitor (Local Supply) The following FURUNO monitors are available for connection to your FCV-2100: MU- 150HD, MU-190 and MU-190HD. Refer to the monitor’s manual for installation. You can use an after-market monitor which has specifications as follows: •...
  • Page 14 1. MOUNTING This page is intentionally left blank.
  • Page 15: Wiring

    WIRING Processor Unit Use the specified cables to connect cables to the processor unit. When the connectors are not used, connector protective caps should be left on the connectors. DVI-D/D S-LINK (option) DVI-D1 To monitor USB3 Not used For maintenance Not used.
  • Page 16 2. WIRING 2.1.2 Control cable, Monitor cable and External connection The control, monitor and external equipments connection ports are behind the con- nector cover on the rear panel. Access the ports and connect cables as shown in the procedure on the following page. Note: The processor unit must be mounted indoors to do this connection because of reduction in waterproofing.
  • Page 17 Trackball control unit cable (5 m) is connected to CONT1 port or CONT2 port. External monitor (XGA resolution only) The FURUNO MU-150HD monitor, or equivalent XGA after-market monitor can be connected as an external monitor. Connect the monitor to the correct port, depending on whether the monitor has analog or digital output.
  • Page 18 2.1.3 Main monitor The following FURUNO monitors are available for connection to your FCV-2100: MU- 150HD, MU-190 and MU-190HD. You can use an after-market monitor also. The after- market monitor should have following display resolutions: XGA, SXGA, Full HD or UXGA or WUXGA.
  • Page 19 2. WIRING 3. Attach the waterproofing gasket to the boot cover, and then pass the DVI-D/D S- LINK cable through the boot cover. DVI-D/D S-LINK cable Gasket Boot cover 4. Attach the DVI-D/D S-LINK cable connector plug to the DVI-D1 port. 5.
  • Page 20: Transceiver Unit

    2. WIRING 9. Attach the waterproofing sheet to the rear of the cable fixing plate. Waterproofing sheet Cable fixing plate 10. Fasten the two binding screws to secure the fixing plate to the boot cover. Binding screw (2 pcs.) 11. Secure the cable to the cable clamp with two cable ties. Note: Cable ties are necessary for waterproofing.
  • Page 21 2. WIRING 2.2.1 Power cable and grounding Connect the plug of power cable (MJ-A3SPF0013-035C, 3.5m) to the 24VDC port. This unit should be grounded to prevent mutual interference. Connect a copper strap (WEA-1004, 1.2m, supplied) between this unit and the ship’s ground. The length of the ground strap should be as short as possible.
  • Page 22 2. WIRING 3. Unplug the WAGO connector (TB1) from the transducer port shown below. WAGO WAGO connecter connecter Terminal opener Terminal opener Transducer 4. Unfasten the seal nut from TRANSDUCER port, and then remove the seal. Claw Seal Seal nut 5.
  • Page 23 2. WIRING 7. Connect the cable to the TB1 connector on the PWRTX board. Confirm that the cores from the WAGO connector are not excessively bent. 8. Secure the shield and drain wires to the grounding terminal next to the connector. See the figure at step 10 for details.
  • Page 24 2. WIRING 2.2.3 Processor unit cable (LAN cable) Connect the processor unit with LAN cable (MOD-Z072-050+, 5m). When using the optional armored cable, peal the external sheath and armor from the cabling. Refer to the following page for armored cable fabrication. Note: Do not connect equipment other than the FCV-2102 or HUB-101 to the NET- WORK port.
  • Page 25 2. WIRING 7. Connect the LAN cable plug to LAN port on the TRX board. Make a loop to prevent stress on the connector. LAN port Make a loop 8. Adjust the cable length then fasten the seal nut to fix the cable.
  • Page 26 2. WIRING 25 mm approx. 9 mm Remove the outer sheath by Expose inner vinyl sheath. Fold back the shield, wrap it approx 25 mm. Be careful onto the outer sheath and not to damage inner shield cut it, leaving 9 mm. and cores.
  • Page 27 2. WIRING 2.2.5 External KP control To control the external KP, connect the external fish finder with a MPYCSLA-4 or equivalent cable (local supply). Refer to the interconnection diagram at end of this manual to connect the cable. 1. Fabricate the cable ends referring to the figure below. 20 20 Drain wire Drain wire...
  • Page 28: Data Sentences

    2. WIRING 7. Reattach the WAGO connector. Fasten the drain wire terminal lug to the chassis with a binding screw. Insert the WAGO connector to TB2 Fasten the terminal lug with a binding screw. 8. Set the gasket assembly and pack them into the seal nut. 9.
  • Page 29: Initial Settings

    The [Advanced Settings] menu window appears. 5. Select the [User Interface Settings] from the menu. The user interface settings appear. Select this icon to reset the current menu settings FCV-2100 [ver 0252446-xx.xx to factory default. Confirm changes and close the menu. Apply changes.
  • Page 30: How To Set The Service Menu

    2. Select [Service] to expand the service menu. The message “Ask your dealer to change service settings.” appears. 3. Press and hold the [OK] button to open the service advanced menu. FCV-2100 [ver 0252446-xx.xx] FCV-2100 [ver 0252446-xx.xx] 10 s later...
  • Page 31 The message window “Settings will be reset.” appears. The setting should be left [Off] while no external monitor is connected. Main monitor: FCV-2100 echo picture Sub monitor: External fish finder • Off: The echo pictures for this equipment and external sounder are displayed...
  • Page 32 3. INITIAL SETTINGS • On: The echo picture for this equipment is displayed on main monitor and the echo picture for external sounder is displayed on sub monitor. To display the echo picture on the sub monitor, select the [External Echo Sounder] icon ™...
  • Page 33: Communication Port Setting

    3. INITIAL SETTINGS Communication Port Setting You can set the communication port (NMEA1/2/3) from the [Tests] menu. To select the signals for communication, do the following. ™ 1. Select the [Advanced Settings] icon ( ) from the InstantAccess bar and se- lect the [Advanced Setting] icon ( ) from the expanded menu bar.
  • Page 34 [Fish size]. You can select more than one datum. The fish size function requires the baud rate set to 38400 bps. 9. For NMEA data type, select a TLL output data from [TLL], [FURUNO-TLL] or [Off]. • [TLL]: Shows L/L data output •...
  • Page 35: External Echo Sounder Setting

    3. INITIAL SETTINGS Communication port monitor The serial signal monitor is available for each port. • Serial Port 1 (NMEA): NMEA1 port on processor unit. (default setting: NMEA) • Serial Port 2 (NMEA): NMEA2 port on processor unit. (default setting: NMEA) •...
  • Page 36 TX trigger is set ‘On’. 2) Select the [Setting Method] to [Model] or [Manual] for transducer in use. • Model: for FURUNO or Airmar transducers. • Manual: for other transducer settings manually. 3) Select the [External Echo Sounder] to [HF] (High Frequency) or [LF] (Low Fre- quency) to set the transducer parameters.
  • Page 37 TX trigger is set ‘On’. 2) Select the [Setting Method] to [Model] or [Manual] for transducer in use. • Model: for FURUNO or Airmar transducers. • Manual: for other transducer settings manually. 3) Select the transducer from the drop down list, from among, B265LH, CM265LH, B275LH-W, CM275LH-W.
  • Page 38: Calibration Setting

    3. INITIAL SETTINGS 4. Press and hold the [OK] button for approximately ten seconds. The service advanced menu for external sounder appears. 5. Select [Shared Settings] to open the [Shared Settings] menu. 6. Select [External Fish Finder] to [On] and select fish finder type (DFF3/ DFF1- UHD).
  • Page 39 3. INITIAL SETTINGS 3. Set the calibration parameters referring to the table below: Item Meaning Setting values Sound speed Calibration for speed of sound. 200.0 to 2000.0 m/s Temperature The water temperature indication is correct- -35.0 to +35.0°F ed. For example, if the actual temperature is 2°C higher than the temperature displayed on screen, set the offset to [+2°C].
  • Page 40 4. Select [OK] to close the menu. 3.5.2 Calibration for external system transducer The calibration procedure for external echo sounder is different from the FCV-2100. There are two method, depending on equipment configuration. External Echo Sounder mode is ‘Off’ ™...
  • Page 41 3. INITIAL SETTINGS Item Meaning Setting values Gain stabilization (LF/HF) Set the antenna position for the -50 to +50 ™ Satellite Compass TD fore-aft/port-stbd Distance (m) from antenna to -100.0 to +100.0 m transducer on the fore-aft/port-stbd line. Enter a positive value for a fore-side transducer.
  • Page 42: Stabilization Setting

    3. INITIAL SETTINGS Item Meaning Setting values Fish size Compensate for incorrect fish size indi- -80 to +100% cations. Setting value (%) Adjustment x1.5 +100 Sound speed Calibration for speed of sound. 200.0 to 2000.0 m/s 6. Set the calibration parameters for bottom level and gain adjust from the [LF/HF] menu under the [Calibration] menu.
  • Page 43 3. INITIAL SETTINGS 2. Select the [Stabilization] menu from the [System] menu. The [Stabilization] menu appears. xx.xx 3. Set [Stabilization] to [On] to enable the stabilization mode. Turn this function on when seas are rough, to get stable pictures regardless of sea conditions.
  • Page 44 3. INITIAL SETTINGS Feature SC-50/110 (Data out setting) SC-30 (IF-NMEASC setting) Format IEC Ed.1 3.6.2 Stabilization for external sounder transducer Set the stabilization menu for external system transducers when the [External sound- er] is set [On]. 1. Move the cursor onto the sub monitor and right-click on the screen The setting menu for external sounder appears.
  • Page 45: Reset To Default Setting

    3. INITIAL SETTINGS Reset to Default Setting To reset all customized settings for advanced setting menus and external sounder set- ting menus to their default settings. The external echo sounder setting should be reset before the reset of main system setting. Do the following procedure. Note: Customized settings cannot be restored.
  • Page 46 3. INITIAL SETTINGS This page is intentionally left blank. 3-18...
  • Page 47: Appendix 1 Jis Cable Guide

    EX: TTYCYSLA - 4 MPYC - 4 TTYCSLA-4 # of cores Designation type Designation type # of twisted pairs The following reference table lists gives the measurements of JIS cables commonly used with Furuno products: Cable Core Cable Core Diameter Type...
  • Page 52 16/Nov/2015 H.MAKI 16/Nov/2015 H.MAKI...
  • Page 54 26/Feb/2016 H.MAKI 26/Feb/2016 H.MAKI...

Table of Contents