APPENDIX 1 MENU TREE
System
Range
TX/RX
Calibration
Stabilization
Service
AP-4
Range1 (7 to 9000 (ft); DFF3: 15; DFF1-UHD: 30)
Range2 (7 to 9000 (ft); DFF3: 30; DFF1-UHD: 60)
Range3 (7 to 9000 (ft); DFF3: 60; DFF1-UHD: 100)
Range4 (7 to 9000 (ft); DFF3: 120; DFF1-UHD: 250)
Range5 (7 to 9000 (ft); DFF3: 200; DFF1-UHD: 450)
Range6 (7 to 9000 (ft); DFF3: 400; DFF1-UHD: 900)
Range7 (7 to 9000 (ft); DFF3: 1000; DFF1-UHD: 1500)
Range8 (7 to 9000 (ft); DFF3: 4500; DFF1-UHD: 2500)
TX Power (DFF3:Off, 1 to 10; DFF1-UHD:Auto, Off, MIN, MAX)
TX Rate (0 to 10)
HF*
TX Pulse (1/4, 1/2, Std, ×2, Manual)
Pulse Length (0.01 (msec) to 5.00 (msec); 1.00 (msec))
RX Band (Narrow, Normal, Wide, Manual)
RX Band Width (0.2 (kHz) to 25.0 (kHz))
LF*
TX Pulse (1/4, 1/2, Std, ×2, Manual)
Pulse Length (0.01 (msec) to 5.00 (msec); 1.00 (msec))
RX Band (Narrow, Normal, Wide, Manual)
RX Band Width (0.2 (kHz) to 25.0 (kHz))
Zero Line Rejection (Off, On)
Zero Line Area (4.5 to 9.8 (ft))
Draft (-30.0 to +99.9 (ft); 0.0)
Fish Size (-80 to +100; 0 (%))
Sound Speed (200.0 to 2000.0 (m/s); 1500.0)
HF
Bottom Level (-40 to +40; 0)
Gain Adjust (-50 to +50; 0)
LF
Bottom Level (-40 to +40; 0)
Gain Adjust (-50 to +50; 0)
Stabilization (Off, On)
Stabilization Sensor (Manual, SC-50, SC-110, SC-30, SC-70*, SC-130*, GS-100)
Delay Time (1 to 1000; 250)
TD fore-aft (-100.0 to +100.0 (m); 0.0)
TD port-stbd (-100.0 to +100.0 (m); 0.0)
ANT TD height (0.0 to 100.0 (m); 0.0)
*: Shown only when
connected to DFF3.
*: SC-70/SC-130 scheduled
for future release.