SYSMODE
SSU
SUB
PRR
Sample Command
SET-SYS-MODE:::TS1000::SYSMODE=SUB;
Sets the system mode to Subtending (SUB). The inputs are set as described in the
table above. Record the mode in
Autonomous Message
A 1176 REPT EVT
OF OPERATION HAS CHANGED,SUB\""
;
Retrieving the Current System Mode
Use the following TL1 command to retrieve the current system mode.
RTRV-SYS-MODE:[<tid>]::[<ctag>];
This command has a default access level of USER.
Response
<value>
097-58001-02 Revision C – August 2005
Set the TimeProvider to SSU operating mode
PRS – Priority 1 and Enabled
INP1 – Priority 2 and Enabled
INP2 – Priority 3 and Enabled
GPS – Disabled
Set the TimeProvider to Subtending operating mode
PRS – Monitor only and Disabled, cannot be
Enabled
INP1 – Priority 1 and Enabled
INP2 – Priority 2 and Enabled
GPS – Monitor only and Disabled, cannot be
Enabled
Set the TimeProvider to Primary Reference
Receiver mode
PRS – Enabled as Backup Reference, can be
set to Monitor or Disabled
INP1 – Enabled as Backup Reference, can be
set to Monitor or Disabled
INP2 – Enabled as Backup Reference, can be
set to Monitor or Disabled
GPS – Enabled and Priority 1
Table
TP-SSU 03-10-24 10:40:10
"SYS,EQPT:NA,SYSMODE,NSA,03-10-24 10-40-10:\"SYSTEM MODE
SSU | SUB | PRR
Chapter 4 Provisioning the TimeProvider
Description
4-3.
Description
Provisioning the IOC
Default value
SSU