Chapter 4 Provisioning the TimeProvider
Provisioning Alarms
Normal Response Format
<cr><lf><lf>
^^^sid^date^time<cr><lf>
M^<ctag>^COMPLD
^^^"<aid>,aidtype:ntfcncde,condtype,srveff,ocrdat,ocrtim
<:condscr>"<cr><lf>*
;
where * indicates zero or more of the preceding element
Response
Value
<aid>
aidtype
ntfcncde
condtype
srveff
ocrdat
ocrtim
condscr
Sample Command
RTRV-ALM:::TS1000;
This command causes the TimeProvider to return all current alarms.
Normal Response
TP-SSU 03-10-24 11:22:11
M
TS1000 COMPLD
"SYS,EQPT:MJ,PWRA,NSA,03-10-24 11-22-11:\"POWER A FAILED\""
"SYS,EQPT:MJ,EXPFAIL,SA,03-10-24 11-22-11:\"EXPANSION CONNECTIVITY FAILED\""
"IOC2,EQPT:MJ,CLKFREE,SA,03-10-24 11-25-15:\"CLOCK ENTERED FREE-RUN MODE\""
"INP1,T1:MN,INPLOS,NSA,03-10-24 11-25-16:\"LOS FAULT\""
"INP2,T1:MN,INPDISQ,NSA,03-10-24 11-25-17:\"INPUT DISQUALIFIED AS POSSIBLE
REFERENCE\""
"INP2,T1:MN,INPLOS,NSA,03-10-24 11-25-17:\"LOS FAULT\""
;
124 TimeProvider User's Guide
Access identifier
Access identifier type
EQPT – alarm associated with operation of the system
T1 – alarm associated with inputs or outputs
Notification code:
MN – Minor alarm
MJ – Major alarm
CR – Critical alarm
Condition type – keyword associated with the command
Service effective indicator
Occurrence date of the alarm
Occurrence time of the alarm
Optional condition description – text string enclosed in quotation
marks
Description