Chapter 6 Maintaining and Troubleshooting the TimeProvider

Diagnosing the IMC

5. Issue the following TL1 command to place the IOC in service:
ED-EQPT::IOC1:::IOCSTATE=INSRV;
6. Install the IOC into the right slot of the shelf and tighten the captive retaining
screws. This IOC will become the Standby IOC.
7. Wait for the IOC to reboot and qualify the reference inputs. During this time the
Active IOC updates the new IOC's memory with current values.
8. Issue the following TL1 command to place the Standby IOC in service:
ED-EQPT::IOC2:::IOCSTATE=INSRV;
Diagnosing the IMC

Reading LED Conditions

Table 6-3
shows the function of the LED indicators on the front panel of the IMC.
Table 6-3. LED Conditions for the IMC
LED Name
Power
Fail
Alarm
Critical
Major
Minor
Alarm Cutoff
(ACO)
152 TimeProvider User's Guide
Condition
Green
Power is On
Off
Power is Off
Red
Card failure
Off
No failure
Red
Card alarm
Off
No alarm
Red
Critical system alarm
Off
No alarm
Red
Major system alarm
Off
No alarm
Yellow
Minor system alarm
Off
No alarm
Green
On
Off
Off
Description
097-58001-02 Revision C – August 2005