Chapter 4 Provisioning the TimeProvider
Setting Communications Parameters
Normal Response
M
;

Setting Ethernet Parameters

Before you can begin using the Ethernet port, you must provision the addresses
using the local Craft or Remote serial port.
If you are not planning to use the Ethernet port, you do not have to provision the
parameters in this section.
Setting the IP Addresses
Use the ED-EQPT command to provision the following IP addresses for the
TimeProvider:
IP Gate address
IP address
IP Subnet address
You can also use this command to echo the <tid> in the response from the
TimeProvider.
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
COMI
IPGATE
IPADDR
IPSUBNET
TIDQUIET
Sample Command
ED-EQPT::COMI:TS1000::IPGATE=127.0.0.1;
This command sets the IP Gate address to 127.0.0.1. Use an appropriate gateway
address for your network, and record the address in
88
TimeProvider User's Guide
TIMEPROVIDER 03-10-24 10:15:04
TS1000 COMPLD
<value>
1.0.0.1
254.255.255.254
1.0.0.1
254.255.255.254
1.0.0.1
255.255.255.254
ENABLE |
DISABLE
Description
Comms ports
IP address of the default gateway
IP address of the Network
Element
IP address of the Network
Element
Enables or disables the echo of
the <tid>. This is a session
setting.
Table
4-3.
097-58001-02 Revision C – August 2005
Default
127.0.0.1
127.0.0.1
255.255.
255.0
DISABLE