Symmetricom TimeProvider 1000 User Manual page 119

Edge clock
Hide thumbs Also See for TimeProvider 1000:
Table of Contents

Advertisement

Description of Alarm
Alarm ID
Condition
EXDSC
Input has had excessive
discontinuities, indicated
by more than 3 signal
faults of the same type
within a 5-minute period.
The alarm clears when
the 5-minute window
contains less than 3
alarms of the same type.
FFOFF
Input has exceeded
FFOFF threshold
MTIE
Input has exceeded at
least 1 of the MTIE
alarm thresholds
INPDISQ
Specified input has
been disqualified or
qualified as a possible
system reference.
INPAIS
The specified input is
receiving an Alarm
Indication Signal.
INPLOS
The specified input has
Loss of Signal.
INPOOF
The specified input is
receiving an Out of
Frame signal.
INPFRQ
Specified input port's
calculated received
frequency exceeds the
pull-in range of the
LO.This alarm condition
disqualifies the input as
a possible reference.
INPPHASE
Specified input port's
phase measurement
exceeds usable value.
097-58001-02 Revision C – August 2005
Possible
Alarm
Levels
NR | NA |
MN | MJ |
CR
<aid> = INP1 or INP2
MN | MJ |
CR
MN | MJ |
CR
1
MN | MJ |
CR
1
MN | MJ |
CR
1
NR | NA |
MN | MJ |
CR
2
NR | NA |
MN | MJ |
CR
Chapter 4 Provisioning the TimeProvider
Error
Error
Delay
Delay
Default
Editable?
IMMED
No
IMMED
No
IMMED
No
FLT
Yes
DELAY
IMMED
No
IMMED
No
IMMED
No
IMMED
No
IMMED
No
TimeProvider User's Guide 119
Provisioning Alarms
Default Level
SSU
SUB
Mode
Mode
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
MN
NR
MN
MN