Parameter
<uid>
<uid>
<username>
<pid>
password
Sample Command
ACT-USER::TECHNICIAN:TS1000::TECH01!;
This command logs in the user named Technician.
Autonomous Message
A 1170 REPT EVT
TECHNICIAN\""
;
Error Response
M 04 DENY
;

Logging Out

Use the following TL1 command to terminate a session and log out of the system.
Security-level users can terminate any other user. The username is not
case-sensitive, but it must be spelled exactly as assigned.
CANC-USER:[<tid>]:[<uid>]:[<ctag>];
This command has a default access level of USER.
<uid>
null
<uid>
097-58001-02 Revision C – August 2005
Up to 20 case-insensitive characters
Up to 20 case-sensitive characters. Must include
at least two non-alphabetic and one special
character (any printing character other than a
letter, number, comma, colon, or semicolon. For
case-sensitive passwords, enclose the <pid> in
quotes, for example "sYmm!23"
TP-SSU 03-10-24 10-18-24
"IMC:NA,LOGIN,NSA,03-10-24 10-18-24:\"USER LOGGED IN,
TP-SSU 03-10-24 10-18-24
<errcode>
"UNAUTHORIZED ACCESS TO THIS SYSTEM IS PROHIBITED."
Value
Up to 20 case-
insensitive characters
Chapter 4 Provisioning the TimeProvider
Value
Description
Terminates the current user's session and
logs the user off the system
Allows a user at the ADMIN or SECURITY
level to terminate another user's session
TimeProvider User's Guide
Managing the User List
Description
Assigned user
name
Assigned
password