Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Table 6-6. Set and Clear Conditions for Alarms
Alarm ID
Set Alarm Conditional Description
EXDSC
Excessive discontinuity fault
FFOFF
FFOFF exceeded threshold
MTIE
MTIE exceeded threshold
TPIUSIG
TPIU signal fault
INPDISQ
Input disqualified as possible
reference
INPAIS
AIS fault
INPLOS
LOS fault
INPOOF
OOF fault
INPFRQ
Frequency threshold exceeded
INPPHASE
Phase error exceeded threshold
INPQL
Quality Level (SSM) exceeded
threshold
INPTRR
Tip/ring reversal on input
EXDSC
Excessive discontinuity fault
MTIE
MTIE exceeded threshold
OUTFAIL
Output fault
SYNTHEOR
Output generator exceeds pull-in range
SYNTHFAIL
Output generator failed
S1LOS
Side 1 LOS fault
S2LOS
Side 2 LOS fault
EXSLIP
Slip rate threshold exceeded
FRMFAULT
Retimer module has a fault
166 TimeProvider User's Guide
PRS and INP[p] Codes
OUT[g] Codes
RTMg[-p] Alarm Conditions
Clear Alarm Conditional Description
Excessive discontinuity cleared
FFOFF within threshold
MTIE within threshold
TPIU signal fault cleared
Input qualified as possible reference
AIS fault cleared
LOS fault cleared
OOF fault cleared
Frequency within threshold
Phase error within threshold
Quality Level (SSM) within threshold
Tip/ring connection correct
Excessive discontinuity cleared
MTIE within threshold
Output fault cleared
Output generator within pull-in range
Output generator restored
Side 1 LOS fault cleared
Side 2 LOS fault cleared
Slip rate within threshold
Retimer module fault has cleared
097-58001-02 Revision C – August 2005