Table 6-7. Alarms (Continued)
Alarm ID
Alarm Condition
Or
Description
CONDTYPE
IOCFAIL
A summary alarm for
failures of the IOC
hardware that are not
specified in other alarms.
BTBCKUP
All BesTime Backup
sources, inputs are
unusable to the
BesTime engine.
CLKBRDG
The local oscillator on
the specified IOC is in
Bridging Mode.
CLKHOLD
The local oscillator on
the specified IOC is in
Holdover Mode.
CLKFREE
The local oscillator on
the specified IOC is in
Free-run mode.
CLKWARM
The local oscillator on
the specified IOC is in
Warm-up mode.
SYNTHEOR The synthesizer
generating the modules
stable output frequency
has reached the defined
End-of-Range for the
type of oscillator used
on the IOC.
IMC2COMM A communication alarm
with the IMC module
and IOC2 module.
IOC2TO
A communication alarm
1COMM
from IOC2 to IOC1.
IOCFAIL
A summary alarm for
IOC BIST faults.
BTBCKUP
All BesTime Backup
sources, inputs are
unusable to the
BesTime engine.
097-58001-02 Revision C – August 2005
Chapter 6 Maintaining and Troubleshooting the TimeProvider
Error
AID
Service
Delay
TYPE
Affecting
Default
EQPT SA
IMMED
EQPT NSA
IMMED
EQPT NSA
IMMED
EQPT SA
IMMED
EQPT SA
IMMED
EQPT SA
IMMED
EQPT SA
IMMED
<aid> = IOC2
EQPT NSA
IMMED
EQPT NSA
IMMED
EQPT SA
IMMED
EQPT NSA
IMMED
Troubleshooting the TimeProvider
Alarm Default
Error
Level
Delay
Editable
SSU PRS SUB
NO
MJ
MJ
NO
__
NA
NO
NA
NO
MJ
MJ
NO
MJ
MJ
NO
MN
MN
NO
MJ
MJ
NO
MN
MN
NO
MN
MN
NO
MJ
MJ
NO
NA
TimeProvider User's Guide 169
MJ
__
MJ
MJ
MN
MJ
MN
MJ