Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
Autonomous Message
A 1189 REPT EVT
THRESHOLD HAS CHANGED,MASK,GPS-R \""
;
Setting Alarm Levels for Performance Monitoring Faults
Once you set a threshold for performance monitoring faults, you can set the alarm
level to indicate that a fault has occurred. Use the SET-ATTR command to set the
alarm level.
SET-ATTR:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
GPS, PRS,
INP1, INP2
MTIE
FFOFF
Sample Command
SET-ATTR::GPS:TS1000::MTIE=MJ;
This command sets the GPS input to report a Major alarm when the MTIE
performance threshold is exceeded.
Autonomous Message
A 1189 REPT EVT
PARAMETER HAS CHANGED,GPS,MJ\""
;
110 TimeProvider User's Guide
TP-SSU 03-10-24 11:09:12
"GPS,EQPT:THRCHG,THRCHG,03-04-05 15-17-57,,,,:\"PM
<value>
NR | NA | MN | MJ | CR
NR | NA | MN | MJ | CR
TP-SSU 03-05-15 09:59:09
"GPS,EQPT:ALMCHG,ALMCHG,03-04-05 15-17-57,,,,:\"ALARM
Description
Input
The alarm level when the specified
input has exceeded at least one of
the MTIE thresholds
The alarm level when the specified
input has exceeded the FFOFF
threshold
097-58001-02 Revision C – August 2005