Provisioning The Input Reference; Setting The Input State - Symmetricom TimeProvider 1000 User Manual

Edge clock
Hide thumbs Also See for TimeProvider 1000:
Table of Contents

Advertisement

Autonomous Message
A 1177 REPT EVT
HAS CHANGED,INSRV\"
;

Provisioning the Input Reference

You need to know the following information about the input reference signal before
you can provision the Input Reference signals:
Input selection mode
Interface type
Frame type/frequency
Quality level
Priority level
SSMs and bit position
CRC

Setting the Input State

Use the ED-EQPT command to provision the inputs to the TimeProvider. You can
enable, disable, or place an input in Monitor mode (where the input is monitored, but
cannot be selected as the system reference).
ED-EQPT:[<tid>]:<aid>:[<ctag>]::<keyword>=<value>;
This command has a default access level of ADMIN.
<aid>
<keyword>
PRS
INPp (p = 1 | 2)
INSTATE
GPS
Sample Command
ED-EQPT::INP1:TS1000::INSTATE=MONITOR;
This command places Input 1 in the Monitor mode.
097-58001-02 Revision C – August 2005
TP-SSU 03-10-24 10:42:40
"IOC1,EQPT:NA,IOCSTATE,NSA,03-10-24 10-42-40:\"IOC STATE
<value>
ENABLE
MONITOR
DISABLE
Chapter 4 Provisioning the TimeProvider
Provisioning the Input Reference
Description
System inputs
Enables the specified input
Places the specified input in
Monitor Only mode.
Disables the specified input
Default value
ENABLE
GPS = DISABLE
TimeProvider User's Guide
99

Advertisement

Table of Contents
loading

This manual is also suitable for:

Timeprovider 1100

Table of Contents