Chapter 6 Maintaining and Troubleshooting the TimeProvider
Troubleshooting the TimeProvider
Table 6-5. Event Codes (Continued)
Event ID
Description
CLRDELAY
Time, in seconds,
before a faulted
signal indicates it is
valid as a system
reference
ELEVTIME
Indicates that Alarm
elevation time (1440
min.) is enabled or
disabled
FACTORY
Indicates that the unit
has been reset to
Factory default. All
modules installed in
the system are reset
FLTDELAY
Time, in seconds,
before faulted signal
indicates it is not
valid as a system
reference
FREEFLT
Indicates if the
Output Fault is issued
when the local
oscillator enters
Free-Run mode.
HOLDFLT
Indicates if the
Output Fault is issued
when the local
oscillator enters
Holdover mode
INPREF
Indicates if the
system automatically
selects another
reference input.
Operator has
enabled the selected
reference input
(REFMODE must be
set to FORCED)
162 TimeProvider User's Guide
Keyword
AID
TYPE
SYS Events
EQPT
EQPT
EQPT
EQPT
EQPT
EQPT
T1
Default Value/
Description of Values
Keyword
5 s
0 to 1000 s
DISABLE
ENABLE | DISABLE
n/a
n/a
10 s
1 to 15 s
SQUELCH
ON – In fault mode,
generate outputs based on
system SSM
AIS – In fault mode,
generate AIS outputs
SQUELCH – In fault mode,
outputs are turned off
ON
ON – In fault mode,
generate outputs based on
system SSM
AIS – In fault mode,
generate AIS outputs
SQUELCH – In fault mode,
outputs are turned off
PRS
PRS – PRS input is
selected as reference
INP1 – INP1 is selected as
reference
INP2 – INP2 is selected as
reference
097-58001-02 Revision C – August 2005